Individually adapted tube current selection and contrast medium injection protocol of coronary CT angiography based on test bolus parameters: a feasibility study

Author:

Zhu Xiaomei1,Shi Zhaofei1,Zhu Yinsu1,Liu Wangyan1,Yang Guanyu2,Yu Tongfu1,Tang Lijun1,Xu Yi1

Affiliation:

1. Department of Radiology, the First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, PR China

2. Laboratory of Image Science & Technology, School of Computer Science and Engineering, Southeast University, Nanjing, Jiangsu, PR China

Abstract

Background Test bolus is mostly used to determine the starting point of a full cardiac scanning with respect to injection of a larger bolus of contrast material. So far there are limited data demonstrating the feasibility of using information obtained from a test bolus to adjust contrast delivery protocols and tube current individually during coronary computed tomography angiography (CCTA). Purpose To evaluate the feasibility of individually adapted tube current selection and contrast injection protocols of CCTA based on test bolus parameters. Material and Methods Test bolus followed by CCTA was performed in 93 patients at 100 kV and in 81 patients at 120 kV, respectively. Simulated attenuation of the descending aorta (SimDA) of CCTA was calculated at a fixed contrast injection rate of 4 mL/s. Univariate and multivariate comparisons were performed to identify associations of SimDA and image noise of CCTA (NoiseCCTA) with test bolus information and patient-related factors including body weight (BW), body mass index (BMI), and body surface area (BSA). Results Compared with BW, BMI, and BSA, SimDA was more closely related to the peak time of left ventricle and peak enhancement of right ventricle obtained from test bolus ( r = 0.495 and r = 0.642 for 100 and 120 kV protocol, respectively). Similarly, NoiseTB was much more closely related to NoiseCCTA ( r = 0.740 and r = 0.630 for 100 and 120 kV protocol, respectively) when compared with BW, BMI, and BSA. Conclusion It is feasible to individually adapt tube current and contrast injection protocol of CCTA based on the information of test bolus.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3