Evaluation of diagnostic accuracy of intracranial aneurysm detection using medical-grade versus commercial consumer-grade displays and different image reconstructions against the background of process optimization for telemedicine

Author:

Auer Timo Alexander1ORCID,Münzfeld Hanna1,Posch Helena1,Stöckel Juliane2,Tietze Anna1,Bohner Georg2,Böning Georg1

Affiliation:

1. Department of Radiology, Charité – University Medicine Berlin, Germany

2. Insitute for Neuroradiology, Charité – University Medicine Berlin, Germany

Abstract

Background Process optimization in computed tomography (CT) and telemedicine. Purpose To compare image quality and objective diagnostic accuracy of medical-grade and consumer-grade digital displays/computer terminals for detection of intracranial aneurysms. Material and Methods Four radiologists with different levels of experience retrospectively read a total of 60 patients including 30 cases of proven therapy-naïve intracranial aneurysm detectable on a medical-grade grayscale calibrated display. They had 5 min per case reading the first 20 datasets using only axial slices, the next 20 patients using axial slices and multiplanar reconstructions (MPRs), and the last 20 patients using axial slices, MPRs, and maximum intensity projections (MIPs). Three months after the first reading session on a medical-grade display, they read all datasets again under the same standardized conditions but on a consumer-grade display. Diagnostic performance, subjective diagnostic confidence, and reading speed were analyzed and compared. Readers rated image quality on a five-point Likert scale. Results Diagnostic accuracy did not differ significantly with areas under the curve of 0.717–0.809 for all readers on both display devices. Sensitivity and specificity did not increase significantly when adding MPRs and/or MIPs. Reading speed was similar with both devices. There were no significant differences in subjective image quality scores, and overall inter-reader variability of all subjective parameters correlated positively between the two devices ( P <0.001–0.011). Conclusion Diagnostic accuracy and readers’ diagnostic confidence in detecting and ruling out intracranial aneurysm were similar on commercial-grade and medical-grade displays. Additional reconstructions did not increase sensitivity/specificity or reduce the time needed for diagnosis.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3