Positron Emission Tomography Compared with Magnetic Resonance Imaging and Computed Tomography in Supratentorial Gliomas Using Multiple Stereotactic Biopsies as Reference

Author:

Mosskin M.1,Ericson K.1,Hindmarsh T.1,von Holst H.1,Collins V. P.1,Bergström M.1,Eriksson L.1,Johnström P.1

Affiliation:

1. From the Departments of Neuroradiology, Diagnostic Radiology, Neurosurgery, Clinical Neurophysiology and Tumor Pathology, Karolinska Sjukhuset, and Karolinska Apoteket, S-10401 Stockholm, Sweden

Abstract

Ten patients with findings at computed tomography (CT) suggesting intracranial supratentorial glioma were investigated to compare the diagnostic efficacy of this technique with that of positron emission tomography (PET) using 11C-methionine and exminations with magnetic resonance (MR). The findings were related to histopathologic examination of serial stereotactic biopsies, which were guided by the appearance of the lesions on PET examination. To obtain corresponding slice orientation with the different examination techniques, an individually shaped helmet fixation was used. However, in 3 cases this fixation device could not be used for MR. Histopathologic diagnosis, obtained in all cases from multiple target stereotactic biopsies, included glioma in 9 patients and reactive gliosis in one case. A detailed comparison of the three imaging techniques and the findings at stereotactic biopsies was possible in 7 patients, while in 3 patients comparison with MR was less exact due to the patient's refusal to wear the helmet during this examination. MR was the most accurate method for outlining the total extent of a lesion, i.e. the tumor and the edema surrounding it. Four lesions had homogeneous signal characteristics and in 6 lesions two (or more) compartments could be distinguished with MR. In 5 cases the MR findings were in complete agreement with the histopathologic findings. However, a thorough correlation between signal characteristics and histology was not possible. Using PET the occurrence and the extent of tumor tissue was correctly predicted in 7 patients. The PET was normal in one case. Findings at CT were in agreement with the histopathologic diagnosis in 5 patients. MR was the most sensitive method for the detection of lesions. PET using methionine appeared to have a somewhat higher capacity to outline correctly the true extent of a tumor. The combination of CT and PET was superior to MR for determining the type and grade of the tumors.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 74 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3