Image evaluation and breast density categories as a function of mammary positioning in full-field digital mammography

Author:

Nakano Irene Tomoko12ORCID,Salvador Gabriel Lucca de Oliveira3ORCID,Schelin Hugo Reuters4,Denyak Valeriy145,Khoury Helen Jamil3,Tacara Silvio2

Affiliation:

1. Pelé Pequeno Príncipe Research Institute, Curitiba, Parana, Brazil

2. Federal Institute of Paraná, Curitiba, Parana, Brazil

3. Federal University of Parana, Department of Radiology, Internal Medicine Branch. Curitiba Parana, Brazil

4. Federal University of Pernambuco, Pernambuco, Brazil

5. National Science Center ‘Kharkov Institute of Physics and Technology’, Akademicheskaya, Kharkiv, Ukraine

Abstract

Background Appropriate mammary positioning is an important factor in optimizing image quality in mammography (MMG). Purpose To study the correlation of quality criteria and breast density classification proposed by the American College of Radiology (ACR) and European Guidelines and its influence to achieve a proper positioning, therefore an adequate MMG. Material and methods A total of 128 routine MMG examinations were reviewed for the definition of breast composition parenchyma and assessment of several quality criteria proposed by the ACR and European Guidelines to achieve an adequate MMG. Adequate MMG was defined as a difference between the posterior nipple line (PNL), difference of the mediolateral oblique (MLO) and craniocaudal (CC) incidences > 1 cm. The quality criteria were analyzed as a function of correlation coefficient in order to evaluate the individual impact of each factor and analysis of variance (ANOVA) for all criteria. Receiver operating characteristic (ROC) curves were plotted to evaluate the performance of the criteria on each type of parenchyma. Results Negative correlation of fatty breasts and visibility of the mammary angle, a greater number of skin folds and PNL > 1 cm (r < 0). Dense MMG presented less visibility of the lateral tissue compared with other categories. Area under the curve of ROC analysis revealed values of 53.1% and 54.7% for the right and left breasts, respectively. Conclusion Several factors influenced in the MMG process, but we find that breast parenchyma has a substantial role in affecting these criteria and therefore a correct position for diagnosis, which could compromise MMG diagnostic performance.

Funder

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Comparison of Automatic and Semiautomatic Approach for the Posterior Nipple Line Calculation;IFMBE Proceedings;2024

2. Realizing Nipple in Profile Recognition and Nipple Detection Using a Single Classification;2023 Asia Pacific Signal and Information Processing Association Annual Summit and Conference (APSIPA ASC);2023-10-31

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3