Accuracy of routine fat-suppressed FLAIR and diffusion-weighted images in detecting clinically evident acute optic neuritis

Author:

McKinney Alexander M1,Lohman Brandon D1,Sarikaya Basar1,Benson Michael1,Lee Michael S2,Benson Manferd T1

Affiliation:

1. Department of Radiology

2. Department Ophthalmology, University of Minnesota Medical Center, Minneapolis, MN, USA

Abstract

Background Contrast-enhanced, fat-suppressed T1-weighted imaging (CET1WI) magnetic resonance imaging (MRI) is quite sensitive in detecting acute optic neuritis (ON), but ON remains a clinical diagnosis. MRI is indicated to evaluate demyelinating brain lesions rather than the optic nerves, while “routine” brain protocols typically include axial FLAIR and DWI. Purpose To evaluate the accuracy of axial, fat-suppressed FLAIR and DWI sequences used for our routine brain imaging in detecting acute ON, as compared to CET1WI and the clinical diagnosis. Material and Methods The clinical data and MRI examinations were retrospectively reviewed of 60 patients presenting to a neuro-ophthalmologist for various visual symptoms. Each patient underwent dedicated neuro-ophthalmologic examination, with axial 5 mm fat-suppressed FLAIR and DWI (part of “routine” brain MRI protocol), as well as 3 mm axial and coronal fat-suppressed CET1WI (part of dedicated orbit MRI protocol). Two neuroradiologists independently evaluated FLAIR and DWI, while CET1WI was reviewed by consensus. Results Thirty-one patients were clinically positive, 29 negative for ON (total = 34 positive and 86 negative nerves). The sensitivities of FLAIR, DWI, and CET1WI for ON were 75.7–77.3%, 77.3%, and 89.5%, respectively; the specificities were 90.5–93.5%, 80.4–82.7%, and 86.0%, respectively; the accuracies were 85.7–88.2%, 79.5–81.1%, and 87.0%, respectively. Inter-observer kappa was 0.783 for FLAIR, and 0.605 for DWI; intra-observer kappa was 0.746–0.816 for FLAIR, and 0.674–0.699 for DWI (each P < 0.0001). Conclusion Being more specific, but not as sensitive, as dedicated CET1WI in acute ON, axial fat-suppressed FLAIR likely has additional value in evaluating for acute ON in “routine” brain MR protocols evaluating for demyelinating disease, while DWI may be hampered by artifacts.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3