Intermediate-weighted MRI with fat suppression (IW-FS): diagnostic performance for bone marrow edema and erosion detection in axial spondyloarthritis

Author:

Chen Min12,Yu Keyan1,Hu Xuehan12,Jans Lennart3,Qi Yulong1,Liu Xin24,Cheng Guanxun1ORCID

Affiliation:

1. Department of Radiology, Peking University Shenzhen Hospital, Shenzhen, PR China

2. Paul C. Lauterbur Research Center for Biomedical Imaging, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, PR China

3. Department of Radiology, Ghent University Hospital, Gent, Belgium

4. University of Chinese Academy of Sciences, Beijing, PR China

Abstract

Background Bone marrow edema (BME) and erosion of the sacroiliac joint are both key lesions for diagnosing axial spondyloarthritis (axSpA) on magnetic resonance imaging (MRI). Purpose To qualitatively and quantitatively compare intermediate-weighted MRI with fat suppression (IW-FS) with T2-weighted short tau inversion recovery (T2-STIR) in assessment of sacroiliac BME and erosion in axSpA. Material and Methods Patients aged 18–60 years with axSpA were prospectively enrolled. All patients underwent a 3.0-T MRI examination of the sacroiliac joints. Para-coronal IW-FS, T2-STIR, and T1-weighted (T1W) images were acquired. BME and erosion were scored by two readers in consensus on IW-FS and STIR using a modified Spondyloarthritis Research Consortium of Canada (SPARCC) scoring system. Consensus scores on T1WI were used as the reference for erosion. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured for BME. Results In total, 49 patients (mean age=33.4 ± 7.6 years) were included. More patients were scored as having BME on T2-STIR (36 vs. 29, P = 0.016). SPARCC-BME score on IW-FS was lower than that acquired on T2-STIR (mean, 11.5 vs. 14.7, P = 0.002). SNR and CNR of BME were both lower on IW-FS than on T2-STIR (mean SNR, 118 vs. 218, P < 0.001; mean CNR, 44 vs. 137, P < 0.001). The sensitivity of erosion detection was higher on IW-FS (83%) than on T2-STIR (54%, P = 0.006). Conclusion IW-FS is not sufficient for BME detection using T2-STIR as the reference standard in patients with axSpA. IW-FS has a much higher sensitivity than T2-STIR for erosion detection in the sacroiliac joint.

Funder

Shenzhen Municipal government

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3