Peripherally inserted central catheters: dependency of radiation exposure from puncture site and level of training

Author:

Jonczyk Martin12,Gebauer Bernhard1,Schnapauff Dirk1,Rotzinger Roman1,Hamm Bernd1,Collettini Federico12

Affiliation:

1. Charité – Universitätsmedizin Berlin, corporate member of Freie Universität Berlin, Humboldt-Universität zu Berlin, and Berlin Institute of Health, Department of Radiology, Berlin, Germany

2. Berlin Institute of Health (BIH), Berlin, Germany

Abstract

Background Several interventional procedures show a dependency on fluoroscopy times (FT) and level of training. Furthermore, FT and dose area products (DAP) vary depending on access site and target vessel for chest port implantations, but not for other thoracic interventions such as percutaneous coronary interventions. Purpose To evaluate the influence of the combination of venous access site and level of training on FTs and DAPs during peripherally inserted central catheters (PICC) implantations in a large cohort of patients. Material and Methods In this retrospective study, PICC implantations of 681 consecutive patients (385 women, 296 men; mean age = 55.0 ± 16.7 years) were analyzed. Two groups of junior (< 50 interventions) and senior (≥ 50 implantations) radiologists were investigated in respect to FT and DAP during PICC placement procedures. Statistical analysis included the Mann–Whitney U test and the Kruskal–Wallis test. P values < 0.05 were considered significant. Results Senior radiologists required significantly less FT (senior = 0.43 s, junior = 0.53 s, P = 0.041), but there was no significant difference in DAPs (senior = 56.3 µGy*m2, junior = 60.6 µGy*m2, P = 0.151). PICC implantations through the left side resulted in a significant reduction of the median FT by 60.9% (left = 0.45 s, right = 1.15 s, P = 0.010). Conclusion Due to considerable dose reduction, the left-sided puncture, especially via the basilic and brachial veins, performed by well-trained interventional radiologists seem to be the preferable approach for PICCs.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3