Computer-aided detection improves brain metastasis identification on non-enhanced CT in less experienced radiologists

Author:

Kato Shimpei1ORCID,Amemiya Shiori1ORCID,Takao Hidemasa1,Yamashita Hiroshi2ORCID,Sakamoto Naoya1,Miki Soichiro1,Watanabe Yusuke1ORCID,Suzuki Fumio1,Fujimoto Kotaro1,Mizuki Masumi1ORCID,Abe Osamu1

Affiliation:

1. Department of Radiology, Graduate School of Medicine, University of Tokyo, Tokyo, Japan

2. Department of Radiology, Teikyo University Hospital, Kawasaki, Kanagawa, Japan

Abstract

Background Brain metastases (BMs) are the most common intracranial tumors causing neurological complications associated with significant morbidity and mortality. Purpose To evaluate the effect of computer-aided detection (CAD) on the performance of observers in detecting BMs on non-enhanced computed tomography (NECT). Material and Methods Three less experienced and three experienced radiologists interpreted 30 NECT scans with 89 BMs in 25 cases to detect BMs with and without the assistance of CAD. The observers’ sensitivity, number of false positives (FPs), positive predictive value (PPV), and reading time with and without CAD were compared using paired t-tests. The sensitivity of CAD and the observers were compared using a one-sample t-test Results With CAD, less experienced radiologists’ sensitivity significantly increased from 27.7% ± 4.6% to 32.6% ± 4.8% ( P = 0.007), while the experienced radiologists’ sensitivity did not show a significant difference (from 33.3% ± 3.5% to 31.9% ± 3.7%; P = 0.54). There was no significant difference between conditions with CAD and without CAD for FPs (less experienced radiologists: 23.0 ± 10.4 and 25.0 ± 9.3; P = 0.32; experienced radiologists: 18.3 ± 7.4 and 17.3 ± 6.7; P = 0.76) and PPVs (less experienced radiologists: 57.9% ± 8.3% and 50.9% ± 7.0%; P = 0.14; experienced radiologists: 61.8% ± 12.7% and 64.0% ± 12.1%; P = 0.69). There were no significant differences in reading time with and without CAD (85.0 ± 45.6 s and 73.7 ± 36.7 s; P = 0.09). The sensitivity of CAD was 47.2% (with a PPV of 8.9%), which was significantly higher than that of any radiologist ( P < 0.001). Conclusion CAD improved BM detection sensitivity on NECT without increasing FPs or reading time among less experienced radiologists, but this was not the case among experienced radiologists.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3