Histogram analysis of apparent diffusion coefficient maps for the differentiation between lymphoma and metastatic lymph nodes of squamous cell carcinoma in head and neck region

Author:

Wang Yan-Jun12,Xu Xiao-Quan1,Hu Hao1,Su Guo-Yi1,Shen Jie1,Shi Hai-Bin1,Wu Fei-Yun1

Affiliation:

1. Department of Radiology, The First Affiliated Hospital of Nanjing Medical University, Nanjing, Jiangsu, PR China

2. Department of Radiology, Zhongda Hospital, Medical School of Southeast University, Nanjing, Jiangsu, PR China

Abstract

Background To clarify the nature of cervical malignant lymphadenopathy is highly important for the diagnosis and differential diagnosis of head and neck tumors. Purpose To investigate the role of first-order apparent diffusion coefficient (ADC) histogram analysis for differentiating lymphoma from metastatic lymph nodes of squamous cell carcinoma (SCC) in the head and neck region. Material and Methods Diffusion-weighted imaging (DWI) data of 67 patients (lymphoma, n = 20; SCC, n = 47) with malignant lymphadenopathy were retrospectively analyzed. The SCC group was divided into nasopharyngeal SCC and non-nasopharyngeal SCC groups. The ADC histogram features (ADC10, ADC25, ADCmean, ADCmedian, ADC75, ADC90, skewness, and kurtosis) were derived and then compared by independent-samples t-test and one-way analysis of variance test, respectively. Receiver operating characteristic curve analyses were employed to investigate diagnostic performance of the significant parameters. Results Lymphoma showed significantly lower ADCmean, ADCmedian, ADC75, and ADC90 than SCC (all P < 0.05). Setting ADC90 = 0.719 × 10–3 mm2/s as the threshold value, optimal diagnostic performance was achieved (area under the curve [AUC] = 0.719, sensitivity = 95.7%, specificity = 50.0%). Subgroup analyses showed no significant difference between lymphoma and NPC (all P > 0.05). Lymphoma showed significantly lower ADC25, ADCmean, ADCmedian, ADC75, and ADC90 than non-nasopharyngeal SCC (all P < 0.05). Optimal diagnostic performance (AUC = 0.847, sensitivity = 86.7%, specificity = 80.0%) could be achieved when setting ADC90 = 0.943 × 10–3 mm2/s as the threshold value. Conclusion Given its limitations, our study has shown that first-order ADC histogram analysis is capable of differentiating lymphoma from metastatic lymph nodes of SCC, especially those of non-nasopharyngeal SCC.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 28 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3