Validation of models in predicting residual disease in ovarian cancer: comparing CT urography with PET/CT

Author:

Lin Lingling1,Liu Qing2,Cheng Jiejun3,Wang Tingting4,Zhou Yan1,Song Mengfan5,Zhou Bin1ORCID

Affiliation:

1. Department of Radiology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, PR China

2. Department of Gynecologic Oncology, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, PR China

3. Department of Radiology, Shanghai First Maternity and Infant Hospital, Tongji University School of Medicine, Shanghai, PR China

4. Department of Nuclear Medicine, Renji Hospital, School of Medicine, Shanghai Jiao Tong University, Shanghai, PR China

5. Department of Obstetrics and Gynaecology, International Peace Maternity and Child Health Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, PR China

Abstract

Background Many ovarian cancer (OC) residual-disease prediction models were not externally validated after being constructed, the clinical applicability needs to be evaluated. Purpose To compare computed tomography urography (CTU) with PET/CT in validating models for predicting residual disease in OC. Material and Methods A total of 250 patients were included during 2018–2021. The CTU and PET/CT scans were analyzed, generating CT-Suidan, PET-Suidan, CT-Peking Union Medical College Hospital (PUMC), and PET-PUMC models. All imagings were evaluated by two readers independently, then compared to pathology. According to surgical outcomes, all patients were divided into the R0 group, with no visible residual disease, and the R1 group, with any visible residual disease. Logistic regression was used to assess the discrimination and calibration abilities of each model. Results CTU and PET/CT showed good diagnostic performance in predicting OC peritoneal metastases based on the Suidan and PUMC model (all the accuracies >0.8). As for model evaluation, the value of correct classification of the CT-Suidan, PET-Suidan, CT-PUMC, and PET-PUMC models was 0.89, 0.84, 0.88, and 0.83, respectively, representing stable calibration. The areas under the curve (AUC) of these models were 0.95, 0.90, 0.91, and 0.90, respectively. Furthermore, the accuracy of these models at the optimal threshold value (score 3) was 0.75, 0.78, 0.80, and 0.80, respectively. All two-paired comparisons of the AUCs and accuracies did not show a significant difference (all P > 0.05). Conclusion CT-Suidan, CT-PUMC, PET-Suidan, and PET-PUMC models had equal abilities in predicting the residual disease of OC. The CT-PUMC model was recommended for its economic and user-friendly characteristics.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology