Use of ABC/2 method for rapidly estimating the target mismatch on computed tomography perfusion imaging in patients with acute ischemic stroke

Author:

Shen Guang-Chen1,Chu Yue1,Ma Gao1,Xu Xiao-Quan1,Lu Shan-Shan1,Shi Hai-Bin2ORCID,Wu Fei-Yun1ORCID

Affiliation:

1. Department of Radiology, the First Affiliated Hospital of Nanjing Medical University, Nanjing, PR China

2. Department of Interventional Radiology, the First Affiliated Hospital of Nanjing Medical University, Nanjing, PR China

Abstract

Background Target mismatch (ischemic core, mismatch volume and mismatch ratio) in patients with acute ischemic stroke (AIS) highly relies on the automated perfusion analysis software. Purpose To evaluate the feasibility and accuracy of using the ABC/2 method to rapidly estimate the target mismatch on computed tomography perfusion (CTP) imaging in patients with AIS, using RAPID results as a reference. Material and Methods In total, 243 patients with anterior circulation AIS who underwent CTP imaging were retrospectively reviewed. Target mismatch associated perfusion parameters were derived from RAPID results and calculated using the ABC/2 method. Paired t-test was used to assess the difference of volumetric parameters between the two methods. The ability of using the ABC/2 method to predict the important cutoff volumetric metrics was also evaluated. Result There was no significant difference in the volumes of ischemic core ( P = 0.068), ischemic area ( P = 0.209), and mismatch volume ( P = 0.518) between ABC/2 and RAPID. Using RAPID results as reference, the ABC/2 method showed high accuracy for predicting perfusion parameters (70 mL and 90 mL: sensitivity=98.5% and 98.5%, specificity=100% and 100%, positive predictive value [PPV]=100% and 100%, negative predictive value [NPV]=93.8% and 92.9%; 10 mL and 15mL: sensitivity=99.6% and 99.5%, specificity=55.6% and 50.0%, PPV=96.6% and 94.8%, NPV=90.9% and 92.3%; 1.2 and 1.8: sensitivity=99.6% and 94.8%, specificity=75.0% and 96.9%, PPV=98.7% and 99.5%, NPV=90.0% and 73.8%). Conclusion The ABC/2 method may be a feasible alternative to RAPID for estimation of target mismatch parameters on CTP in patients with AIS.

Funder

National Natural Science Foundation of China

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3