Impact of transjugular intrahepatic portosystemic shunt implantation on liver perfusion measured by volume perfusion CT

Author:

Preibsch Heike1,Spira Daniel2,Thaiss Wolfgang M1,Syha Roland1,Nikolaou Konstantin1,Ketelsen Dominik1,Lauer Ulrich M3,Horger Marius1

Affiliation:

1. University Department of Radiology, Diagnostic and Interventional Radiology, Tübingen, Germany

2. University Medical Center Heidelberg, Diagnostic and Interventional Radiology, Heidelberg, Germany

3. University Department of Medicine – Department of Internal Medicine, Gastroenterology, Hepatology and Infectious Diseases, Tübingen, Germany

Abstract

Background Implantation of a transjugular intrahepatic portosystemic shunt (TIPS) induces changes of liver perfusion. Purpose To determine the changes in arterial, portal venous, and total perfusion of the liver parenchyma induced by TIPS using the technique of volume perfusion computed tomography (VPCT) and compare results with invasively measured hepatic intravascular pressure values. Material and Methods VPCT quantification of liver perfusion was performed in 23 patients (mean age, 62.5 ± 8.8 years) with portal hypertension in the pre-TIPS and post-TIPS setting, respectively. A commercially available software package was used for post-processing, enabling separate calculation of the dual (arterial [ALP] and portal venous [PVP]) blood supply and additionally of the hepatic perfusion index (HPI) (HPI = ALP/(ALP + PVP)*100%). Invasive pressure measurements were performed during the intervention, before and after TIPS placement. Liver function tests performed before and after the procedure were compared. Results Mean decrease of pressure gradient through TIPS was 13.3 mmHg. Mean normal values for ALP, PVP, and total perfusion (ALP + PVP) before TIPS were 15.9, 37.7, and 53.5 mL/100 mL/min, respectively, mean HPI was 35.4%. After TIPS, ALP increased to a mean value of 37.7 mL/100 mL/min, PVP decreased (15.7 mL/100 mL/min, P < 0.05), whereas total perfusion remained unchanged (53.4 mL/100 mL/min, P = 0.97). HPI increased (71.9%; P < 0.05). No correlation between invasive pressure measurement and VPCT parameters was observed. After TIPS, liver function tests were found to worsen with a significant increase of bilirubin ( P < 0.05). Conclusion Following TIPS placement, ALP and HPI increased in all patients, whereas PVP markedly decreased. Interestingly, the magnitude of decrease in portosystemic pressure gradients was not found to correlate with VPCT parameters.

Publisher

SAGE Publications

Subject

Radiology Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology