Maintaining immobilization devices on trauma patients during chest and pelvic X-ray: a feasibility study

Author:

Stokkeland Pål Johan1ORCID,Andersen Erlend2,Bjørndal Maria Myhre1,Moen Anita Imeland1,Aslaksen Sindre3,Grasaas-Albrecht Chris Peter4,Hyldmo Per Kristian56

Affiliation:

1. Department of Radiology, Sørlandet Hospital Kristiansand, Kristiansand, Norway

2. Clinic for Medical Services, Sørlandet Hospital Kristiansand, Kristiansand, Norway

3. The Norwegian Air Ambulance Foundation, Drøbak, Norway

4. Emergency Department, Sørlandet Hospital Kristiansand, Kristiansand, Norway

5. Trauma Unit, Sørlandet Hospital, Kristiansand, Norway

6. Faculty of Health Sciences, University of Stavanger, Stavanger, Norway

Abstract

Background Most trauma systems and traumatic spinal injury guidelines mandate spinal stabilization from the site of injury to a radiological confirmation or refutal of spinal injury. Vacuum mattresses have been advocated for patients in need of prehospital spinal stabilization. Purpose To investigate the effect of different vacuum mattresses on standard resuscitation bay conventional radiography of chest and pelvis, especially regarding artefacts. Material and Methods We used a mobile X-ray machine to perform chest and pelvic conventional radiography on an anthropomorphic whole-body phantom with a trauma transfer board, three different vacuum mattresses, and without any stabilization device. The vacuum mattresses were investigated in activated, deactivated, and stretched after deactivated states. Two radiologists assessed the artefacts independently. Agreement was measured using kappa coefficient. Results All radiographs were of good technical quality and fully diagnostic. With the exception of one disagreed occurrence, artefacts were seen to hamper clinical judgment exclusively with activated vacuum mattresses. There was substantial agreement on artefact assessment. The observed agreement was 0.82 with a kappa coefficient of 0.71. The first vacuum mattress caused no artefacts hampering with clinical judgment. Conclusion Our study concludes that it is feasible to maintain some vacuum mattresses through resuscitation bay conventional radiography of chest and pelvis. They do not result in artefacts hampering with clinical judgment. Our vacuum mattress No. 1 is recommendable for this purpose. Together with our previous findings our present results indicate that some vacuum mattresses may be used throughout the initial resuscitation bay assessment and CT examination.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3