Digital tomosynthesis of the thorax: the influence of respiratory motion artifacts on lung nodule detection

Author:

Kim Sung Mok1,Chung Myung Jin1,Lee Kyung Soo1,Kang Hee1,Song In-Young1,Lee Eun Joo1,Hwang Hye Sun1

Affiliation:

1. Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea

Abstract

Background Digital tomosynthesis considerably reduces problems created by overlapping anatomy compared with chest X-ray (CXR). However, digital tomosynthesis requires a longer scan time compared with CXR, and thus may be vulnerable to motion artifacts. Purpose To compare the diagnostic performance of digital tomosynthesis in subjects with and without respiratory motion artifacts. Material and Methods The institutional review board approved this retrospective study, and the requirement for written informed consent was waived. A total of 46 subjects with imaging containing respiratory motion artifacts were enrolled in this study, 18 of whom were positive and 28 of whom were negative for lung nodules on computed tomography (CT). The control group was comprised of 92 age-matched subjects with imaging devoid of motion artifacts. Of these, 36 were positive and 56 were negative for lung nodules on subsequent CT scan. The size criteria of nodules were 4–10 mm. Three chest radiologists independently evaluated the radiographs and digital tomosynthesis images for the presence of pulmonary nodules. Multireader multicase receiver-operating characteristic (ROC) analyses was used for statistical comparisons. Results Within the control group, the areas under curve (AUC) for observer performances in detecting lung nodules on digital tomosynthesis was higher than that on CXR ( P = 0.017). Within the study group, there were no significant differences in AUCs for observer performances ( P = 0.576). Conclusion When no motion artifacts are present, the detection performance of nodules (4–10 mm) on digital tomosynthesis is significantly better than that on CXR, whereas there is not a significant difference in cases with motion artifacts.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 14 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3