Coronary stent imaging with dual-source CT: assessment of lumen visibility using different convolution kernels and postprocessing filters

Author:

Ulrich Anne1,Burg Matthias C1,Raupach Rainer2,Bunck Alexander13,Schuelke Christoph1,Maintz David3,Heindel Walter1,Seifarth Harald14

Affiliation:

1. Department of Clinical Radiology, University of Muenster, Münster, Germany

2. Siemens Medical Solutions, Computed Tomography CTE PA, Forchheim, Germany

3. Department of Radiology, University Hospital of Cologne, Cologne, Germany

4. Department of Diagnostic and Interventional Radiology, Esslingen Hospital, Esslingen, Germany

Abstract

Background Assesment of the coronary arteries after stent placement using coronary computed tomography angiography (CCTA) currently requires reconstruction of images with soft kernels for the assessment of atherosclerotic plaques and dedicated edge enhancing kernels for the evaluation of the stent lumen. Purpose To evaluate a two-dimensional filter tool that provides instant postprocessing of images reconstructed with soft kernels into edge-enhanced images and vice versa and thus may eliminate the need for two separate reconstrcutions for the assessment of coronary artery stents using CCTA. Material and Methods Twenty stents with a diameter of 3.0 mm placed in a vascular phantom were scanned with a dual-source CT using standard parameters. Images were reconstructed with a soft B30f and an edge-enhancing B46f kernel and postprocessed with the corresponding filter algorithm (F30 for B30f images; F46 for B46f images). The resulting four data-sets were evaluated for lumen visibility, intraluminal attenuation, and image noise by two independent readers. Results were validated in vivo against invasive coronary angiography in data-sets from patients with coronary artery stents. Results Average intraluminal attenuation was 552.6 HU, 527.3 HU, 207.9 HU, and 267.5 HU for B30f, F30, B46f, and F46 images, respectively ( P < 0.0001). Average image noise was 11.3, 10.6, 19.2, and 15.0 HU, respectively ( P < 0.0001). The visible stent diameter was significantly higher in the B46f (59.6%) and F46 images (54%) compared to the B30f (48.3%) and F30 (51.5%) images ( P < 0.0001). In the patient study, lumen assessability was significantly better in B46f images than in F46 images. Sensitivity for stenosis detection was best in the original B46f images with a sensitivity of 67% and a specificity of 94%. Conclusion The postprocessing filter reduces image noise, however currently it does not offer an alternative to image reconstruction using the edge-enhancing kernels for the evaluation of the stent lumen.

Publisher

SAGE Publications

Subject

Radiology, Nuclear Medicine and imaging,General Medicine,Radiological and Ultrasound Technology

Cited by 15 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3