Third generation of laser (>1900) for endovenous thermoablation (EVLA) of varicose veins: A systematic review and meta-analysis

Author:

Palombi Luca1ORCID,Morelli Monica2,Bruzzese Dario3,Quarto Gennaro4

Affiliation:

1. Advanced Surgical Phlebology Service, Villa Salus Hospital, Villa Salus Foundation, Mestre, Italy

2. Private Practice, Rome, Italy

3. Medical Statistics, Department of Public Health, University of Naples Federico II, Naples, Italy

4. Department of Clinical Medicine and Surgery, University of Naples Federico II, Naples, Italy

Abstract

Objectives Third generation lasers with longer wavelengths (>1900 nm) have been introduced, in recent years, for the treatment of varicose veins. The possible advantage of the new generation lasers is that they allow complete damage to the vein wall using a lower Power in Watts (W: J/sec) and a lower linear energy density (LEED: J/cm). The aim of this work is to evaluate the results present in the literature regarding efficacy and safeness of the new generation lasers for the treatment of varicose veins. Methods Published articles were searched on PubMed database and on Cochrane Library, entering the keywords “1940 nm or 1920 nm laser AND varicose veins laser thermoablation (EVLA).” The primary endpoint of the study was to value rate of occlusion and adverse events at the short term follow-up. The search yielded a total of 14 studies. In the end, only six studies were judge eligibility. Results The studies were heterogenous in their documentation, EVLA, duplex ultrasound protocol and result reporting. A total of 540 limbs of 377 patients were treated with endovenous laser ablation (EVLA) with laser 1920–1940 nm. The treated veins had a mean diameter of 0.74 ± 0.17 cm and a mean length of 27.87 ± 20.63 cm. The pooled estimates of immediate occlusion rate was of 99.8% (95% CI: 97.9% to 100.0) with high heterogeneity (I2 = 60%; 95% PI: 89.7% to 100%), while at short-term follow-up was of 98.2% (95% CI: 94.0% to 100.0%) with higher heterogeneity (I2:79%; 95% PI: 77.1% to 100.0%). EHIT occurred in 7 cases (pooled estimate: 0.7%). The other adverse events rate reported were 1% of hyperpigmentation, 2.8% of neurological complications, 0.6% thrombophlebitis and 1.9% of bruising/hematoma. The pooled mean estimates of LEED was equal to 38.2 J/cm (95% CI: 26.3 to 50.1 J/cm) although with a very large heterogeneity (I2 = 100%). Conclusions The overall success rate of EVLA was high. The analysis of these studies suggests that using lower parameters (Power and linear administered energy) may have no effect on the treatment success rate. Short-term results demonstrate comparable occlusion rates respect the second-generation lasers. Instead, data suggest a low complication rates. Short-term results demonstrate comparable complications rates respect the second-generation lasers (1300-1470 nm). Randomized studies with longer follow-up are required to evaluate the EVLA 1900 nm procedure further.

Publisher

SAGE Publications

Subject

Cardiology and Cardiovascular Medicine,General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3