Ultrasonographic and histological evaluation of the effects of long-term carotid catheterization on cardiac function in NMRI mice

Author:

Teilmann Anne C1,Thomsen Morten B2,Ihms Elizabeth A3,Pate Nathan3,Hau Jann1,Abelson Klas1

Affiliation:

1. Department of Experimental Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark

2. Department of Biomedical Sciences, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark

3. Department of Molecular and Comparative Pathobiology, Johns Hopkins University, Baltimore, Maryland, USA

Abstract

Catheterization of laboratory mice is commonly performed in biomedical research to infuse substances and for blood sampling. One approach is to catheterize the right common carotid artery and advance the catheter until the tip is positioned in the aorta or the proximal brachiocephalic trunk. Owing to the small body size of the mouse, a catheter tends to occupy a great part of even the larger vessel lumens, and this may increase vascular resistance with potential pathophysiological impacts on the heart. The present study compared cardiac function of catheterized mice, with catheter tip placement in the brachiocephalic trunk, with sham-operated mice and non-operated control mice. During four weeks post-catheterization, M-mode echocardiography measurements of the thickness of the left ventricular anterior wall, left ventricular inner diameter and the thickness of the left ventricular posterior wall were performed. The left ventricular volume, ejection fraction and fractional shortening were calculated. Moreover, aortic recordings of the thickness of the medial and lateral walls as well as the inner diameter were measured. Terminally, histological analysis of the hearts was conducted, and body weights and heart weights were compared between groups. No effects on echocardiography parameters, histology, body weights or cardiac weights could be found between groups. In the present study, implantation of a carotid catheter with catheter tip placement in the proximal brachiocephalic trunk had minimal influence on cardiac and aortic physiology and did not induce significant cardiac changes.

Publisher

SAGE Publications

Subject

General Veterinary,Animal Science and Zoology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3