Does Interfraction Cone Beam Computed Tomography Improve Target Localization in Prostate Bed Radiotherapy?

Author:

Elakshar Sara12ORCID,Tsui James Man Git12,Kucharczyk Michael Jonathan1ORCID,Tomic Nada3,Fawaz Ziad Simon1ORCID,Bahoric Boris1,Papayanatos Joseph1,Chaddad Ahmad1,Niazi Tamim1

Affiliation:

1. Department of Oncology, Division of Radiation Oncology, McGill University, Jewish General Hospital, Montreal, Quebec, Canada

2. They are co-first authors and have contributed equally to this manuscript.

3. Physics Department, McGill University, Jewish General Hospital, Montreal, Quebec, Canada

Abstract

Purpose: In this prospective phase II study, we investigated whether cone beam computed tomography scan was a superior method of image-guided radiotherapy relative to 2D orthogonal kilovoltage images in the post-radical prostatectomy setting. Methods: A total of 419 treatment fractions were included in this analysis. The shifts required to align the patient for each treatment were performed using 3D matching between cone beam computed tomography scans and the corresponding computed tomography images used for planning. This was compared with the shifts obtained from 2D orthogonal kilovoltage images, matching with the corresponding digitally reconstructed radiographs. Patients did not have fiducials inserted to assist with localization. Interfractional changes in the bladder and rectal volumes were subsequently measured on the cone beam computed tomography images for each fraction and compared to the shift differences between orthogonal kilovoltage and cone beam computed tomography scans. The proportion of treatment fractions with a shift difference exceeding the planning target volume of 7 mm, between orthogonal kilovoltage and cone beam computed tomography scans, was calculated. Results: The mean vertical, lateral, and longitudinal shifts resulted from 2D match between orthogonal kilovoltage images and corresponding digitally reconstructed radiographs were 0.353 cm (interquartile range: 0.1-0.5), 0.346 cm (interquartile range: 0.1-0.5), and 0.289 cm (interquartile range: 0.1-0.4), compared to 0.388 cm (interquartile range: 0.1-0.5), 0.342 cm (interquartile range: 0.1-0.5), and 0.291 cm (interquartile range: 0.1-0.4) obtained from 3D match between cone beam computed tomography and planning computed tomography scan, respectively. Our results show a significant difference between the kilovoltage and cone beam computed tomography shifts in the anterior–posterior direction ( P = .01). The proportion of treatment fractions in which the differences in kilovoltage and cone beam computed tomography shifts between exceeded the 7 mm planning target volume margin was 6%, 2%, and 3% in the anterior–posterior, lateral, and superior–inferior directions, respectively. Conclusion: We prospectively demonstrated that the daily use of volumetric cone beam computed tomography for treatment localization in post-radical prostatectomy patients demonstrated an increased need for a shift in patient position. This suggests that in post-radical prostatectomy patients the daily cone beam computed tomography imaging improved localization of the prostate bed and may have prevented a limited number of geographic misses, compared to daily kilovoltage imaging that was not assisted with fiducials.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3