Bronchial Artery Chemoembolization With Radiopaque Doxorubicin Eluding Beads in Patients With Malignant Hemoptysis from Metastatic Lung Cancer

Author:

Nezami Nariman12ORCID,Georgiades Christos3,Hong Kelvin K.3,Buethe Ji3

Affiliation:

1. Division of Vascular and Interventional Radiology, Department of Diagnostic Radiology and Nuclear Medicine, University of Maryland School of Medicine, Baltimore, MD, USA

2. Experimental Therapeutics Program, University of Maryland Marlene and Stewart Greenebaum Comprehensive Cancer Center, Baltimore, MD, USA

3. Division of Vascular and Interventional Radiology, Department of Radiology and Radiological Sciences, the Johns Hopkins Hospital, Baltimore, MD, USA

Abstract

Purpose:This pilot study was designed to assess the technical feasibility and safety of bronchial artery chemoembolization with radiopaque doxorubicin eluting beads (DEB-BACE) in patients with malignant hemoptysis from pulmonary metastasis. Materials & Methods: Four patients underwent DEB-BACE using 70-150 μm radiopaque DEB (LC Beads LUMI, Boston Scientific). Beads delivery and deposition were assessed under fluoroscopy and cone beam computed tomography (CT), respectively. Results: All 4 procedures were technically successful. Beads delivery and deposition were successfully visualized under fluoroscopy and cone beam CT guidance in all cases. Hemoptysis was resolved after embolization in all 4 patients. There were no adverse events or immediate or early complications after DEB-BACE. Two patients (50%) required repeat DEB-BACE within 1 week due to recurrent hemoptysis, and 1 patient had DEB-BACE 1.5 years later due to recurrent hemoptysis from the contralateral lung. All targeted lesions decreased in size in follow-up studies (mean 16 months, range 1-33 months). One patient died of progressive cancer disease invading the heart 1 month after DEB-BACE. Conclusions: DEB-BACE using radiopaque LC Beads LUMI loaded with doxorubicin is technically feasible and safe for controlling hemoptysis and cancer progression in patients with metastatic lung tumors. Visualization of beads delivery under fluoroscopy and deposition of beads under cone beam CT facilitate delivery of beads and embolization of bronchial arteries.

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3