Cardiac Dose Control and Optimization Strategy for Left Breast Cancer Radiotherapy With Non-Uniform VMAT Technology

Author:

Qiu Jianjian1ORCID,Zhang Shujun1,Lv Bo1,Zheng Xiangpeng1

Affiliation:

1. Huadong Hospital, Fudan University, Shanghai, China

Abstract

Purpose: A novel in-house technology “Non-Uniform VMAT (NU-VMAT)” was developed for automated cardiac dose reduction and treatment planning optimization in the left breast radiotherapy. Methods: The NU-VMAT model based on IGM (gantry MLC Movement coefficient index) was established to optimize the volumetric modulated arc therapy (VMAT) MLC movement and modulation intensity in certain gantry angles. The ESAPI embedded in Eclipse® was employed to connect TPS and the optimization program via I/O relevant DICOM RT files. The adjuvant whole-breast radiotherapy of 14 patients with left breast cancer was replanned using our NU-VMAT technology in comparison with VMAT and IMRT technology. Dosimetric parameters including D1%, D99%, and Dmean of PTV, V5, V10, and V20 of ipisilateral lung, V5, D20, D30, and Dmean of heart, monitor units (MUs), and delivery time derived from IMRT, VMAT, and NU-VMAT plans were evaluated for plan quality and delivery efficiency. The quality assurance (QA) was conducted using both point-dose and planar-dose measurements for all treatment plans. Results: The IGM−NU−VMAT curves with plan optimization (range from 50% to 147%) were converged more significantly than IGM-VMAT curves (range from 0% to 297%). The dose distribution requirements of the target and normal tissues could be met using IMRT, VMAT, or NU-VMAT; the lowest Dmean was achieved in NU-VMAT plans (5.38 ± 0.46 Gy vs 5.63 ± 0.61 Gy in IMRT and 7.95 ± 0.52 Gy in VMAT plans). Statistically significant differences were found in terms of delivery time and MU when comparing IMRT with VMAT and NU-VMAT plans ( P < .05). In comparison with IMRT plans, the MU and delivery time in NU-VMAT plans dramatically decreased by 69.8% and 28.4%, respectively. Moreover, NU-VMAT plans showed a high gamma passing rate (96.5% ± 1.11) in plane dose verification and minimal dose difference (2.4% ± 0.19) in point absolute dose verification. Conclusion: Our non-uniform VMAT facilitated the treatment strategy optimization for left breast cancer radiotherapy with dosimetric advantage in cardiac dose reduction and delivery efficiency in comparison with the conventional VMAT and IMRT.

Funder

Shanghai Municipal Commission of Health

Shanghai Municipal Commission of Science and Technology

National Natural Science Foundation of China

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3