Clinically Oriented Target Contour Evaluation Using Geometric and Dosimetric Indices Based on Simple Geometric Transformations

Author:

Xian Lixun123,Li Guangjun13ORCID,Xiao Qing1,Li Zhibin1,Zhang Xiangbin1,Chen Li1,Hu Zhenyao1,Bai Sen1

Affiliation:

1. Department of Radiation Oncology, Cancer Center and State Key Laboratory of Biotherapy, West China Hospital, Sichuan University, Chengdu, Sichuan, China

2. Department of Oncology, Chengdu Second People’s Hospital, Chengdu, Sichuan, China

3. *Lixun Xian and Guangjun Li are contributed equally to this work.

Abstract

Purpose: In radiotherapy, geometric indices are often used to evaluate the accuracy of contouring. However, the ability of geometric indices to identify the error of contouring results is limited primarily because they do not consider the clinical background. The purpose of this study is to investigate the relationship between geometric and clinical dosimetric indices. Methods: Four different types of targets were selected (C-shaped target, oropharyngeal cancer, metastatic spine cancer, and prostate cancer), and the translation, scaling, rotation, and sine function transformation were performed with the software Python to introduce systematic and random errors. The transformed contours were regarded as reference contours. Dosimetric indices were obtained from the original dose distribution of the radiotherapy plan. The correlations between geometric and dosimetric indices were quantified by linear regression. Results: The correlations between the geometric and dosimetric indices were inconsistent. For systematic errors, and with the exception of the sine function transformation (R2: 0.023-0.04, P > 0.05), the geometric transformations of the C-shaped target were correlated with the D98% and Dmean (R2: 0.689-0.988), 80% of which were P < 0.001. For the random errors, the correlations obtained by the all targets were R2 > 0.384, P < 0.05. The Wilcoxon signed-rank test was used to compare the spatial direction resolution capability of geometric indices in different directions of the C-shaped target (with systematic errors), and the results showed only the volumetric geometric indices with P < 0.05. Conclusions: Clinically, an assessment of the contour accuracy of the region-of-interest is not feasible based on geometric indices alone. Dosimetric indices should be added to the evaluations of the accuracy of the delineation results, which can be helpful for explaining the clinical dose response relationship of delineation more comprehensively and accurately.

Funder

National Natural Science Foundation of China

Publisher

SAGE Publications

Subject

Cancer Research,Oncology

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3