Numerical modeling and seismic evaluation of masonry-infilled reinforced concrete frames retrofitted with carbon fiber–reinforced polymer wraps

Author:

Pan Xiaolan123,Yan Jiachuan123,Wang Zhenyu123,Zou Chaoying123

Affiliation:

1. Key Lab of Structures Dynamic Behavior and Control of the Ministry of Education, Harbin Institute of Technology, Harbin, China

2. Key Lab of Smart Prevention and Mitigation of Civil Engineering Disasters of the Ministry of Industry and Information Technology, Harbin Institute of Technology, Harbin, China

3. School of Civil Engineering, Harbin Institute of Technology, Harbin, China

Abstract

This article investigates the efficiency of various retrofitting schemes using carbon fiber–reinforced polymers in improving the seismic performance of a substandard masonry-infilled reinforced concrete frame. One virtual five-story reinforced concrete frame was designed according to out-of-date Chinese codes. In total, 15 carbon fiber–reinforced polymers retrofitting schemes were adopted before earthquakes, and three sets of earthquakes representing low, medium, and high frequency contents were selected to conduct the incremental dynamic analysis. The influence of infills’ collapse due to out-of-plane effect was discussed detailedly, and then, the effectiveness of different retrofitting schemes was evaluated. It was found that the collapse of infills obviously reduced the seismic capacity and finally resulted in a soft-story failure mechanism for the reinforced concrete frame. For earthquakes with low frequency content, the enhancement efficiency of retrofitting infills or both columns and infills was increased with the increase in the number of retrofitted stories; however, for medium and high earthquake frequency contents, retrofitting infills or both columns and infills were inefficient when less than half of the structure height was retrofitted. Among the adopted 15 schemes, carbon fiber–reinforced polymers retrofit of both columns and infills along the full building height was found to be the most efficient. Improper selection of a retrofitting scheme could lead to the change of soft-story location. The inter-story drift ratio capacity of effectively retrofitted frames can meet the requirements of current seismic code.

Publisher

SAGE Publications

Subject

Building and Construction,Civil and Structural Engineering

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3