Affiliation:
1. Department of Structural Engineering, University of California–San Diego, San Diego, CA, USA
2. Department of Civil Engineering, National Taiwan University
Abstract
This study aims to validate a piezoelectric driven-rod scour monitoring system that can sense changes in scour depth along the entire rod at its instrumented location. The proposed sensor is a polymeric slender rod with a thin strip of polyvinylidene fluoride that runs through its midline. Extraction of the fundamental frequency allows the direct calculation of the exposed length (or scour depth) of the slender rod undergoing fluid flow excitation. First, laboratory validation in dry conditions is presented. Second, hydrodynamic testing of the sensor system in a soil-bed flume is discussed. Each rod was installed using a three-dimensional-printed footing designed for ease of installation and stabilization during testing. The sensors were installed in a layout designed to capture symmetric scour conditions around a scaled pier. In order to analyze the system out of steady-state conditions, water velocity was increased in stages during testing to induce different degrees of scour. As ambient water flow excited the portion of the exposed rods, the embedded piezoelectric element outputted a time-varying voltage signal. Different methods were then employed to extract the fundamental frequency of each rod, and the results were compared. Further testing was also performed to characterize the relationship between frequency outputs and flow velocity, which were previously thought to be independent. In general, the proposed driven-rod scour monitoring system successfully captured changing frequencies under varied flow conditions.
Funder
Engineer Research and Development Center
Subject
Building and Construction,Civil and Structural Engineering
Cited by
12 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献