Automation on an Open-Access Platform of Alzheimer’s Disease Biomarker Immunoassays

Author:

Gille Benjamin12,Dedeene Lieselot1,Stoops Erik3,Demeyer Leentje3,Francois Cindy3,Lefever Stefanie1,De Schaepdryver Maxim14,Brix Britta5,Vandenberghe Rik678,Tournoy Jos289,Vanderstichele Hugo3,Poesen Koen14

Affiliation:

1. Laboratory for Molecular Neurobiomarker Research, Department of Neurosciences, KU Leuven, Leuven, Belgium

2. Department of Chronic Disease, Metabolism and Ageing, KU Leuven, Leuven, Belgium

3. ADx NeuroSciences, Gent, Belgium

4. Laboratory Medicine, University Hospitals Leuven, Leuven, Belgium

5. Euroimmun AG, Lübeck, Germany

6. Department of Neurology, University Hospitals Leuven, Leuven, Belgium

7. Laboratory for Cognitive Neurology, Department of Neurosciences, KU Leuven, Leuven, Belgium

8. Alzheimer Research Centre KU Leuven, Leuven Institute of Neuroscience and Disease, Leuven, Belgium

9. Department of Clinical and Experimental Medicine, KU Leuven, Leuven, Belgium

Abstract

The lack of (inter-)laboratory standardization has hampered the application of universal cutoff values for Alzheimer’s disease (AD) cerebrospinal fluid (CSF) biomarkers and their transfer to general clinical practice. The automation of the AD biomarker immunoassays is suggested to generate more robust results than using manual testing. Open-access platforms will facilitate the integration of automation for novel biomarkers, allowing the introduction of the protein profiling concept. A feasibility study was performed on an automated open-access platform of the commercial immunoassays for the 42-amino-acid isoform of amyloid-β (Aβ1–42), Aβ1–40, and total tau in CSF. Automated Aβ1–42, Aβ1–40, and tau immunoassays were performed within predefined acceptance criteria for bias and imprecision. Similar accuracy was obtained for ready-to-use calibrators as for reconstituted lyophilized kit calibrators. When compared with the addition of a standard curve in each test run, the use of a master calibrator curve, determined before and applied to each batch analysis as the standard curve, yielded an acceptable overall bias of −2.6% and −0.9% for Aβ1−42 and Aβ1–40, respectively, with an imprecision profile of 6.2% and 8.4%, respectively. Our findings show that transfer of commercial manual immunoassays to fully automated open-access platforms is feasible, as it performs according to universal acceptance criteria.

Publisher

Elsevier BV

Subject

Medical Laboratory Technology,Computer Science Applications

Cited by 7 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3