Interobserver and Intraobserver Reliability of Two Classification Systems for Intra-articular Calcaneal Fractures

Author:

Lauder Anthony J.1,Inda David J.2,Bott Aaron M.3,Clare Michael P.1,Fitzgibbons Timothy C.2,Mormino Matthew A.1

Affiliation:

1. Orthopaedics, University of Nebraska, Omaha, NE

2. Orthopaedics, Gross, Iverson, Kratochvil, Klein, P.C., Omaha, NE

3. Orthopaedics, University of Texas, Medical School, Houston, TX

Abstract

Background: For a fracture classification to be useful it must provide prognostic significance, interobserver reliability, and intraobserver reproducibility. Most studies have found reliability and reproducibility to be poor for fracture classification schemes. The purpose of this study was to evaluate the interobserver and intraobserver reliability of the Sanders and Crosby-Fitzgibbons classification systems, two commonly used methods for classifying intra-articular calcaneal fractures. Methods: Twenty-five CT scans of intra-articular calcaneal fractures occurring at one trauma center were reviewed. The CT images were presented to eight observers (two orthopaedic surgery chief residents, two foot and ankle fellows, two fellowship-trained orthopaedic trauma surgeons, and two fellowship-trained foot and ankle surgeons) on two separate occasions 8 weeks apart. On each viewing, observers were asked to classify the fractures according to both the Sanders and Crosby-Fitzgibbons systems. Interobserver reliability and intraobserver reproducibility were assessed with computer-generated kappa statistics (SAS software; SAS Institute Inc., Cary, North Carolina). Results: Total unanimity (eight of eight observers assigned the same fracture classification) was achieved only 24% (six of 25) of the time with the Sanders system and 36% (nine of 25) of the time with the Crosby-Fitzgibbons scheme. Interobserver reliability for the Sanders classification method reached a moderate ( kappa = 0.48, 0.50) level of agreement, when the subclasses were included. The agreement level increased but remained in the moderate ( kappa = 0.55, 0.55) range when the subclasses were excluded. Interobserver agreement reached a substantial ( kappa = 0.63, 0.63) level with the Crosby-Fitzgibbons system. Intraobserver reproducibility was better for both schemes. The Sanders system with subclasses included reached moderate ( kappa = 0.57) agreement, while ignoring the subclasses brought agreement into the substantial ( kappa = 0.77) range. The overall intraobserver agreement was substantial ( kappa = 0.74) for the Crosby-Fitzgibbons system. Conclusions: Although intraobserver kappa values reached substantial levels and the Crosby-Fitzgibbons system generally showed greater agreement, we were unable to demonstrate excellent interobserver or intraobserver reliability with either classification scheme. While a system with perfect agreement would be impossible, our results indicate that these classifications lack the reproducibility to be considered ideal.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 39 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3