Malreduction of the Tibiofibular Syndesmosis in Ankle Fractures

Author:

Gardner Michael J.1,Demetrakopoulos Demetris1,Briggs Stephen M.1,Helfet David L.1,Lorich Dean G.1

Affiliation:

1. New York, NY

Abstract

Background: Diagnosis and reduction of syndesmosis injuries in ankle fractures can be challenging. Previous studies have demonstrated that standard radiographic measurements used to evaluate the integrity of the syndesmosis are inaccurate. The purpose of this study was to determine the adequacy of standard postoperative radiographic measurements in assessing syndesmotic reduction compared to CT and to determine the prevalence of postoperative syndesmotic malreduction in a patient cohort. Methods: Twenty-five patients with ankle fractures and syndesmotic instability who had open reduction and syndesmotic fixation were evaluated. All patients had a standard radiographic series postoperatively followed by a CT scan. Radiographic measurements were made by three observers to determine the tibiofibular relationship. Axial CT scan images were judged for quality of reduction of the syndesmosis by measuring the distance between the fibula and the anterior and posterior facets of the incisura. Differences between the anterior and posterior measurements of more than 2 mm were considered incongruous. Results: Six patients (24%) had evidence of postoperative diastasis using the radiographic criteria, four of whom had evidence of malreduction on postoperative CT scan. Conversely, 13 patients (52%) had incongruity of the fibula within the incisura on CT scan (average 3.6 mm, range 2.0 to 8.0 mm), only four of whom had one or more abnormal radiographic measurements. In 10 (77%) of the 13 malreductions seen on CT scan, the posterior measurement was greater, indicating that internal rotation or anterior translation of the fibula may have occurred. Sensitivity of radiographs was 31% and the specificity was 83% compared to CT. Conclusions: Many syndesmoses were malreduced on CT scan but went undetected by plain radiographs. Radiographic measurements did not accurately reflect the status of the distal tibiofibular joint in this series of ankle fractures. Furthermore, postreduction radiographic measurements were inaccurate for assessing the quality of the reduction. Although we did not seek to correlate functional outcomes, the known morbidity of postoperative syndesmotic malreduction should lead to heightened vigilance for assessing accurate syndesmosis reduction intraoperatively.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3