Effectiveness of Headless Bioabsorbable Screws for Fixation of the Scarf Osteotomy

Author:

Kim Jin su1,Cho Hun ki2,Young Ki Won2,Lee Sang young2,Kim Ji soo2,Lee Kyoungtae3

Affiliation:

1. Surgery of Foot and Ankle, CM chungmu general hospital, Yeongdeuon-po, Seoul, Republic of Korea

2. Surgery of Foot and Ankle, Eulji Medical Center, College of Medicine, Eulji University, Seoul, Republic of Korea

3. KT Lee’s Orthopedic Hospital, Seoul, Republic of Korea

Abstract

Background: Scarf osteotomy has been used in hallux valgus surgery due to its large fixation surface for screws and low postoperative complications. However, screws may cause skin irritation from their head, which may require an additional surgical procedure to remove. Methods: This study included 115 patients (106 females and 9 males, 115 feet) who underwent hallux valgus correction with a scarf osteotomy using bioabsorbable screws between September 2010 and September 2012. Preoperative and postoperative 1-month and 1-year radiographic measurements, including intermetatarsal angle (IMA), hallux valgus angle (HVA), distal metatarsal articular angle (DMAA), proximal phalangeal articular angle (PPAA), and lateral translational distance (LTD), were obtained. American Orthopaedic Foot & Ankle Society (AOFAS) hallux/forefoot scores were used for patient satisfaction. Results: Preoperative mean values of HVA, IMA, and PPA of 32.8 degrees, 14.6 degrees, and 7.52 degrees, respectively, improved to 10.7 degrees, 6.0 degrees, and 4.6 degrees, respectively at 1-year follow up ( P < .05). The difference in LTD between the 1-month and 1-year follow-up was not statistically significant. AOFAS hallux/forefoot score improved from 69.1 to 96.1 at the 1-year follow up ( P < .001). Complete screw absorption was not seen radiographically. Sixteen feet had complications reported. One patient complained of skin irritation over a small protrusion of the screw, and another patient had a foreign body reaction. There were 3 patients with neurologic injury from a popliteal block and 3 patients with dorsal cutaneous nerve symptoms. Four feet had metatarsal fracture during surgery. Conclusion: We found the scarf osteotomy using bioabsorbable screws to have satisfactory clinical and radiographic results with a low complication rate. Level of Evidence: Level IV, case series.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 8 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3