Comparison of the Syndesmotic Staple to the Transsyndesmotic Screw: A Biomechanical Study

Author:

Marqueen Timothy1,Owen John1,Nicandri Gregg1,Wayne Jennifer1,Carr James1

Affiliation:

1. Department of Orthopaedic Surgery and Biomedical Engineering, Virginia Commonwealth University, Richmond, VA

Abstract

Background: Controversy still exists about treatment of syndesmotic injuries. This study compared the fixation strengths and biomechanical characteristics of two types of ankle fracture syndesmotic fixation devices: the barbed, round staple and the 4.5-mm cortical screw. Methods: Cadaveric testing was done on 21 fresh-frozen knee disarticulation specimens in biaxial servohydraulic Instron testing equipment. Submaximal torsional loads were applied to specimens in intact and Weber C bimalleolar fracture states. The specimens were then fixed with one of two techniques and again subjected to submaximal torsion and torsion to failure. Biomechanical parameters measured included tibiofibular translation and rotation, maximal torque to failure, and degrees of rotation at failure. Results: Compared to the intact state before testing, the staple held the fibula in a more anatomic position than the screw for mediolateral and anterior displacements (p < 0.01). With submaximal torsional testing, the staple restored 85% of the tibiofibular external rotation and all of the posterior translation values as compared to the intact state. The screw resulted in 203% more tibiofibular medial translation and 115% more external rotation than the intact state. The degree of tibial rotation during submaximal torsional loading was restored to within 15% of intact values but was 21% less with the screw. There was no statistical difference between the screw and staple when tested in load to failure. Tibio-talar rotation at failure was statistically different with the staple construct, allowing more rotation as compared to the screw. Conclusion: The staple restored a more physiologic position of the fibula compared to the syndesmotic screw. Both provided similar performance for the load to failure testing, while the screw reduced tibial rotation more after cyclic loading. There was more tibial rotation before failure for the staple, suggesting a more elastic construct. This study provides biomechanical data to support the clinical use of the syndesmotic staple.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3