Background: Radiation exposure from diagnostic imaging procedures is associated with increased cancer risk. No published data currently exist regarding ionizing radiation exposure in total ankle replacement surgery. This study quantified intraoperative fluoroscopic dose and duration during ankle replacement surgery and examined patient and technical factors affecting the level of exposure. Methods: Fifty-five patients underwent ankle replacement using STAR, Salto-Talaris, or INBONE total ankles. Intraoperative fluoroscopic dose and duration, patient demographics, implant design, and accompanying additional procedures were documented for each case. The relationship between each relevant variable and radiation dose and time was determined. Results: The mean fluoroscopic dose and duration for all cases were 1.15 ± 0.84 milliGray per case and 77 ± 34 seconds per case, respectively. There was a positive correlation between the absorbed radiation dose and the duration of fluoroscopy ( r = .50, P < .001). The mean fluoroscopic doses were 1.53 milliGray, 0.99 milliGray, and 0.88 milliGray for INBONE, STAR, and Salto-Talaris prostheses, respectively. Fluoroscopic dose was significantly influenced by implant design ( P = .035), with implants using an intramedullary referencing guide associated with higher radiation doses. After excluding cases requiring additional procedures, the fluoroscopic time and radiation dose associated with intramedullary referencing guide implants continued to exceed those of the other implants, but the differences were no longer statistically significant ( P = .22, P = .09, respectively). Conclusion: The average patient radiation dose during total ankle replacement was approximately one-fifth the recommended maximum yearly radiation exposure. The radiation dose was positively associated with fluoroscopy duration. Among factors controllable by the surgeon, selection of an implant with an extramedullary alignment system and conscious effort to minimize duration of fluoroscopy can reduce harmful radiation exposure and decrease cancer risk in total ankle replacement patients and associated operating room personnel. Level of Evidence: Level III, comparative series.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3