Comparative Study of Intramedullary Hammertoe Fixation

Author:

Obrador Caterina1,Losa-Iglesias Marta2,Becerro-de-Bengoa-Vallejo Ricardo3,Kabbash Christina A.4

Affiliation:

1. Medcare Orthopedics and Spine Hospital, Dubai, United Arab Emirates

2. Facultad de Ciencias de la Salud, Universidad Rey Juan Carlos, Alarcón, Madrid, Spain

3. Departamento de Enfermería, Escuela de Enfermería, Fisioterapia y Podología, Universidad Complutense, Ciudad Universitaria, Madrid, Spain

4. Greater Hartford Orthopaedic Group, St Francis Hospital and Medical Center, Hartford, CT, USA

Abstract

Background: Temporary Kirschner wire fixation (K-wire) is a widely used, low-cost fixation method for the correction of hammertoe deformity. Reported complications associated with K-wires prompted the development of new implants over the past decade. However, there is a lack of literature on comparative studies analyzing functional outcomes using validated questionnaires. The purpose of this study was to analyze functional outcomes in patients who had undergone proximal interphalangeal joint fusion using 2 types of intramedullary implant, the Smart Toe and the TenFuse, and to compare them with the outcomes in patients treated with standard K-wire fixation. Methods: A retrospective review of operative hammertoe correction by a single surgeon was performed in 96 patients followed for more than 12 months. Functional outcome was assessed using the Foot Function Index (FFI), the Short Form 36 (SF-36), and the 10-point visual analog scale (VAS) validated questionnaires. Complications and fusion rates were also evaluated. Several patients in the study underwent corrections in different toes; thus, a total of 186 toes were included in the study. From these, 65 toes (34.9%) were treated with K-wire fixation, 94 (50.5%) with Smart Toe titanium implant, and 27 (14.5%) with TenFuse allograft implant. Results: No statistically significant differences in functional outcome and incidence of complications were observed among the 3 fixation groups, although the 2 intramedullary implants were associated with greater fusion rates and patient satisfaction. Breakage of the Smart Toe implant was significantly higher than that of the other fixations, with 10.6% of implants breaking within the first year postoperatively. SF-36 and VAS scores decreased 12 months after surgery for the 3 types of fixation, with no statistically significant differences observed. Conclusion: The use of Smart Toe and TenFuse implants provided operative outcomes comparable to those obtained using a K-wire fixation and slightly better patient satisfaction. Our results suggest that utilization of these implants for hammertoe correction was a reasonable choice that provided good alignment, pain reduction, and improved function at final follow-up. However, they are more expensive than K-wires. For this reason, in-depth cost-benefit studies would be required to justify their use as a standard treatment. Level of Evidence: Level III, comparative series.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 23 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370