Utility of Volumetric Measurement via Weight-Bearing Computed Tomography Scan to Diagnose Syndesmotic Instability

Author:

Bhimani Rohan1ORCID,Ashkani-Esfahani Soheil1,Lubberts Bart1ORCID,Guss Daniel123,Hagemeijer Noortje C.14ORCID,Waryasz Gregory123,DiGiovanni Christopher W.123

Affiliation:

1. Foot & Ankle Research and Innovation Laboratory, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA

2. Department of Orthopaedic Surgery, Foot & Ankle Service, Massachusetts General Hospital, Boston, MA, USA

3. Newton-Wellesley Hospital, Harvard Medical School, Massachusetts General Hospital, Boston, MA, USA

4. Department of Orthopaedic Surgery, Amsterdam University Medical Center, University of Amsterdam, Amsterdam Movement Sciences, Amsterdam, the Netherlands

Abstract

Background: Weight-bearing computed tomography (WBCT) allows evaluation of the distal syndesmosis under physiologic load. We hypothesized that WBCT volumetric measurement of the distal syndesmosis would be increased on the injured as compared to the contralateral uninjured side and that these 3-dimensional (3D) calculations would be a more sensitive determinant than 2-dimensional (2D) methodology among patients with syndesmotic instability. Methods: Twelve patients with unilateral syndesmotic instability requiring operative fixation who underwent preoperative bilateral foot and ankle WBCT were included in the study group. The control group consisted of 24 patients without ankle injury who underwent similar imaging. On WBCT scan, 2D measurements of the syndesmosis joint were first measured 1 cm above the joint line in the axial plane via syndesmotic area and distances between the anterior, middle, and posterior quadrants. Thereafter, comparative 3D volumetric measurements of the syndesmotic joint were also calculated: (1) from the tibial plafond extending until 3 cm proximally, (2) 5 cm proximally, and (3) 10 cm proximally. Results: In patients with unilateral syndesmotic instability, all 3 weight-bearing volumetric measurements were significantly larger on the injured side as compared to the contralateral, uninjured side ( P < .001). In the control group, there was no difference between syndesmotic volumes at any level. Of these 3 anatomic reference points, the 3D measurement spanning from the tibial plafond to a level 5 cm proximally had the highest relative volumetric ratio between the injured and uninjured side, suggesting it is the most sensitive in distinguishing between stable and unstable syndesmotic injury ( P < .001). Notably, this 3D volumetric measurement was also more sensitive than 2D measurements ( P = .001). Conclusion: 3D volumetric measurement of the syndesmosis joint appears to be the most effective way to diagnose syndesmotic instability, compared with more traditional 2D syndesmosis measurement. Level of Evidence: Level III, retrospective comparative study.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 54 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3