Treatment of Hypertrophic Distal Tibia Nonunion and Early Malunion With Callus Distraction

Author:

Schoenleber Scott Jacob1,Hutson James Jackson1

Affiliation:

1. Department of Orthopaedics, University of Miami/Jackson Memorial Hospital, Miami, FL, USA

Abstract

Background: Hypertrophic nonunions and early malunions of pilon and distal tibia fractures result in complex, challenging to treat deformities. Callus distraction histiogenesis is an option for their management, allowing for the simultaneous correction of multiplanar deformity and limb length discrepancy. Methods: A single-surgeon, retrospective case series was performed. Eight patients (6 males and 2 females) who were treated with callus distraction from 1991 to 2011 were reviewed. Six of 8 patients had varus deformities (range, 8-19 degrees) and 2 patients had valgus deformities (both 16 degrees) of the distal tibia metaphysis. Six of 8 had apex anterior deformities (range, 2-21 degrees) and 2 had apex posterior deformity (range, 9-20 degrees). An Ilizarov fixator or Taylor Spatial Frame (Smith & Nephew, Memphis, TN) was used to distract the nonunion or early malunion to correct alignment and shortening. Preoperative and postoperative radiographic outcomes, limb alignment, and ankle-hindfoot scores were reviewed. Results: Union was achieved in all patients at a mean of 5.8 months (range, 4.1-7.6 months). The 3 patients treated with an Ilizarov-type fixator had deformity correction to within 5 degrees of neutral in 1 plane and to within 10 degrees in the other plane. All 5 patients treated with a Taylor Spatial Frame had correction to within 5 degrees of neutral alignment in both coronal and sagittal planes. There were 2 complications requiring reoperation and 1 persistent limb length discrepancy (2 cm) after treatment. Median AOFAS ankle-hindfoot score was 82.5 (range, 53-90) at an average follow-up of 30.4 months (range, 8-92). Conclusions: Callus distraction histiogenesis was a minimally invasive technique that can successfully treat patients with hypertrophic nonunion and early malunion of the distal tibia. We believe the application of a computer-assisted 6-axis frame to correct the deformity improved the correction of these multiplanar deformities. Level of Evidence: Level IV, case series.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3