Affiliation:
1. Department of Orthopaedics, University of Southern California, Keck School of Medicine, Los Angeles, CA
Abstract
Twenty-four patients with displaced ankle fractures awaiting surgery were randomized to a study (n = 11) or a control group (n = 13). In the study group, patients had a pulsatile cold compression (PCC) device applied to their ankle, and remained at bed rest with the extremity elevated while awaiting surgery. In the control group patients remained in a posterior molded splint instead of the PCC device. Baseline circumferential measurements of the ankle were obtained, followed by measurements at 24-hour increments to evaluate edema resolution. In addition, patient satisfaction with use of the PCC device was evaluated with a scale ranging from 1 to 4. The median decrease of circumference in the study group compared to the control group was 0.5 cm vs. 0.1 cm at 24 hours (p=0.005), 0.9 cm vs. 0.4 cm at 48 hours (p<0.001), and 1.2 cm vs. 0.5 cm at 72 hours (p=0.009). The ratio of the decrease in circumference relative to the circumference of the normal ankle was significantly higher in the PCC group compared to the control group at all time points. All patients in the PCC group were satisfied with the device (median satisfaction score = 4). The PCC device was well tolerated and resulted in a significantly greater reduction of ankle circumference at 24, 48, and 72 hours after its application, compared to splinting and elevation alone. The PCC device facilitates edema resolution following ankle fractures.
Subject
Orthopedics and Sports Medicine,Surgery
Cited by
34 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献