Background: Preoperative navigation has provided many potential benefits for total knee arthroplasty, including patient-specific alignment, repeatable implant placement, and decreased operative time. For the first time, this technology was applied to total ankle arthroplasty (TAA). This study evaluated repeatability of tibia and talus patient-specific guide placement and deviation between the preoperative plan and actual implant placement. Methods: Routine ankle CT scans were acquired of 15 cadaveric lower extremity limbs, converted into 3D solid models, and imported into a computer-assisted design assembly. Anatomic landmarks defining tibia/talus alignment were established and used to perform a virtual TAA. Commercially available implant components were placed to mimic traditional cases. An operative guide referencing the cadaver-specific anatomy was engineered to define the resection planes necessary to re-create virtual placement of traditional tibia and talus implants in the postoperative position. Board-certified TAA orthopaedic surgeons with no prior preoperative navigation experience placed the operative guides onto the bones based on tactile and visual feedback. Guide placement was repeated 4 times to determine variability. Final implant position was recorded with an infrared probe, confirmed with CT scans, and compared to the preoperative plan. Average deviations between planned and actual guide placement were determined for all rotational and translational degrees of freedom (DOF). In addition, implant component location was measured radiographically. Results: Intraobserver tibia and talus guide variation between all trials was 0.26 ± 0.18 degrees and 0.36 ± 0.25 degrees in flexion/extension, 0.61 ± 0.58 and 0.53 ± 0.53 in varus/valgus, and 0.79 ± 0.38 degrees and 1.15 ± 0.77 degrees in internal/external rotation, respectively. Average variation between preoperative and postoperative implant placement was less than 2 degrees and 1.4 mm in all specimens tested. Conclusion: Preliminary data suggest that preoperative navigation and custom operative guides result in reliable and reproducible placement of TAA implants and patient-specific ankle alignment. Deviation of final implant placement from the preoperative plan was less than 2 degrees in all angular DOF, providing greater accuracy than the ±3 degrees determined in other implant system studies using traditional instrumentation and computer navigation. Clinical Relevance: We have further demonstrated that final implant position is successfully guided by these patient-specific guides, with reproducibility of tibial component placement falling within 2 degrees of the intended target. This level of reproducibility suggests a promise for this technology, and it is hoped this level of accuracy will become the benchmark for the next generation of total ankle arthroplasty.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 68 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3