Background: Great variability exists in methods of stabilization for syndesmotic disruptions of the ankle. We hypothesized that syndesmotic screw fixation with 3.5-mm fully threaded cortical screws through either three or four cortices would have similar strength and rate of mechanical failure and that retention of screws after fracture healing would not result in adverse clinical symptoms. Methods: In a prospective, surgeon-randomized study at a Level-one trauma center, 127 patients with syndesmotic disruptions were treated surgically. Seven patients were lost to followup, leaving 120 for review. Syndesmotic disruptions were stabilized with 3.5-mm fully threaded cortical screws placed through three or four cortices. Screws were removed only if symptomatic. Outcome criteria were screw failure, loss of reduction, and need for hardware removal. Results: Fifty-nine patients received fixation through three cortices and 61 patients received fixation through four cortices. Mean follow-up was 150 days. In the group with stabilization through three cortices, hardware failure occurred in five patients (8%) and three had a loss of reduction. In the group with stabilization through four cortices, hardware failure occurred in four patients (7%); all were asymptomatic and did not require screw removal. There was no loss of reduction in that group. Comparing the two groups using binary logistic analysis, there was no difference in loss of reduction ( p = 0.871), screw breakage ( p = 0.689), or need for hardware removal ( p = 0.731). Conclusion: The data suggest that either three or four cortices of fixation can be used when stabilizing syndesmotic injuries of the ankle. There was a trend towards higher loss of reduction in the group with tricortical fixation when weightbearing restrictions were not followed. Retention of the syndesmotic screws, even with mechanical failure, does not pose a clinical problem. Weightbearing can be allowed at 6 to 10 weeks without routine removal of screws.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 128 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3