Hallux Metatarsophalangeal Joint Arthrodesis Using Dome-Shaped Reamers and Dorsal Plate Fixation: A Prospective Study

Author:

Goucher Nicholas R.12,Coughlin Michael J.13

Affiliation:

1. Boise, ID

2. Carlton-Harrison Orthopedic Clinic, Ogden, UT

3. Idaho Orthopedic Foot and Ankle Fellowship, Boise, ID

Abstract

Background: Many techniques exist for arthrodesis of the first metatarsophalangeal (MTP) joint, as well as, indications for each method. The purpose of this study was to determine the results of one method using dome-shaped reamers to prepare the joint surfaces and a low-profile dorsal titanium plate for internal fixation. To date, no prospective studies have reported patient outcomes of arthrodesis of the first MTP joint using this technique. Methods: Fifty patients (54 feet) had first MTP joint arthrodesis from January, 2004, through January, 2005. All patients were evaluated preoperatively for underlying pathology, pain, function, and radiographic findings. First MTP joint arthrodesis was fixed with a dorsal titanium plate with preset valgus and dorsiflexion after the joint surfaces were prepared with matching male and female dome-shaped power reamers to achieve congruous cancellous bone surfaces. At a minimum of 1-year followup, patients returned for postoperative evaluation. In addition to evaluation of pain, function, and radiographic findings, patients were asked how long they remained off work, how long swelling persisted, and whether the hardware caused symptoms. Results: Forty-nine of 53 patients returned for followup at an average of 16 months after surgery. American Orthopaedic Foot and Ankle Society (AOFAS) scores improved significantly (z = −6.301, p > 0.01) from an average of 51 points preoperatively (range 24 to 97) to 82 points postoperatively (range 47 to 90). Pain scores at final followup demonstrated a significant improvement (z = −6.154, p > 0.01) from a mean of 6.3 to a mean of less than 1 point on the visual analog pain scale. Time off work averaged 3 weeks, while swelling persisted for an average of 11 weeks. Thirty-five feet in 32 patients (66%) were rated as excellent, 16 feet in 16 patients (30%) were rated as good, and two feet (4%) in one patient were rated as fair, with none reporting a poor result. There were four nonunions (8%), with one being a fibrous union having no progression of deformity. Three of four patients with a nonunion reported a good result subjectively with the fourth reporting a fair result. Conclusions: The 96% satisfaction rate in 49 patients indicates that first MTP joint arthrodesis with a low-profile contoured dorsal titanium plate and crossed lag screws after joint preparation with dome-shaped reamers is both reliable and reproducible. The union rate was high (92%), and the revision rate was low (4%).

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3