Biomechanical Comparison of 4 Different Lateral Plate Constructs for Distal Fibula Fractures

Author:

Eckel Tobin T.1,Glisson Richard R.1,Anand Prashanth1,Parekh Selene G.12

Affiliation:

1. Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA

2. Ajunct Faculty, Duke Fuqua School of Business, Durham, NC, USA

Abstract

Background: Displaced lateral malleolar fractures are often treated with reduction and surgical stabilization. However, there has not been a comprehensive laboratory comparison to determine the most appropriate device for treating these patients. This study subjected a range of contemporary lateral fibular plates to a series of mechanical tests designed to reveal performance differences. Methods: Forty fresh frozen lower extremities were divided into 4 groups. A Weber B distal fibula fracture was simulated with an osteotomy and stabilized using 1 of 4 plate systems: a standard Synthes one-third tubular plate with interfragmentary lag screw, a Synthes LCP locking plate with lag screw, an Orthohelix MaxLock Extreme low-profile locking plate with lag screw, or a TriMed Sidewinder nonlocking plate. Controlled monotonic bending and cyclic torsional loading were applied and bending stiffness, torsional stiffness, and fracture site motion were quantified. Resistance to cyclic torsional loading was determined by quantifying the number of loads withstood before excessive rotation occurred. Correlation between bone mineral density and each of the mechanical measures was determined. Results: There was no difference in angulation or bending stiffness between plates. All plates except the LCP showed greater lateral deflection than in the other bending directions. Bending stiffness was lowest in lateral distal fragment deflection for all 4 plates. There was a positive correlation between bone mineral density and bending stiffness for all plate types. There was no difference in fracture site rotation between plate types in internal or external torsion, but internal rotation of the distal fragment consistently exceeded external rotation. Torsional stiffness in external rotation exceeded stiffness in internal rotation in nearly all specimens. LCP plates performed relatively poorly under cyclic torsion. Conclusions: Significant differences in plate performance were not demonstrated. The effects of bone quality variability and differences in interfragmentary screw purchase resulted in data dispersion that confounded absolute ranking of plate performance. Clinical Relevance: Identification of an optimal lateral fibular plating system has the potential to improve the clinical outcome of malleolar fracture fixation, particularly when patient conditions are unfavorable.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 36 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. [Translated article] Fractures of the peroneal malleolus: Current concepts;Revista Española de Cirugía Ortopédica y Traumatología;2024-09

2. Fracturas del maléolo peroneo: conceptos actuales;Revista Española de Cirugía Ortopédica y Traumatología;2024-09

3. Use of locking fibular plates versus non-locking dual plate fixation: A biomechanical study;Journal of Clinical Orthopaedics and Trauma;2024-06

4. Management of non-unions of the malleolar fractures- Current Evidence;Journal of Clinical Orthopaedics and Trauma;2024-04

5. Pull-out strength of screws in long bones at different insertion angles: finite element analysis and experimental investigations;Materials Testing;2024-01-23

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3