Abstract

Background: Internal fixation of osteoporotic ankle fractures is technically difficult and may fail because of unreliable purchase. This study was undertaken to determine if a combination of a hook plate and tibial pro-fibular screws can provide secure fixation until fracture union. Methods: Thirty-one patients between the ages of 55 and 90 years had open reduction and internal fixation of ankle fractures between April, 2001, and April, 2003. Sixteen patients with an average age of 71.4 years had ankle fracture fixation with a combination of hook plate and tibial pro-fibular screws for the distal fibular fracture, and 15 patients with an average age of 71.9 years had fixation of their ankle fractures with standard fixation technique using AO/ASIF principles but no tibial pro-fibular screws. All patients were followed with clinical and radiologic assessment at 2 weeks, 6 weeks, and 12 weeks postoperatively. At an average of 15.8 months after injury, patients also completed a mailed questionnaire with the Olerud-Molander ankle score and the AOFAS ankle-hindfoot score for preoperative and postoperative status. Results: All patients who had tibial pro-fibular screw fixation had fracture union without hardware failure or complications. In the standard fixation group two patients had wound breakdown and one had a valgus malunion with screw pull out. The AOFAS and Olerud-Molander scores for the standard open reduction and internal fixation were 57.3 and 82.8 before injury and 37 and 43.8 postoperatively, respectively. The AOFAS and Olerud-Molander scores for the hook plate and tibial pro-fibular fixation group were 55.9 and 81.3 before injury and 42.4 and 50.3 postoperatively, respectively. Conclusions: The combination of hook plate and tibial pro-fibular screws in osteoporotic ankle fractures in a series of patients has not been reported before. This novel technique provides stable fixation for osteoporotic ankle fractures in elderly patients until union is achieved with good clinical scores.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 41 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3