Bone Suture Anchor Fixation in the Lower Extremity: A Review of Insertion Principles and a Comparative Biomechanical Evaluation

Author:

Scranton Pierce E.1,Lawhon S. Michael1,McDermott John E.1

Affiliation:

1. Seattle, WA

Abstract

Background: Suture anchors have been developed for the fixation of ligaments, capsules, or tendons to bone. These devices have led to improved fixation, smaller incisions, earlier limb mobility, and improved outcomes. They were originally developed for use in shoulder reconstructions but are now used in almost all extremities. In the lower leg they are used in the tibia, the talus, the calcaneus, tarsal bones, and phalanges. Nevertheless, techniques for insertion and mechanisms of failure are not well described. Methods: Five suture anchors were studied to determine the pullout strength in four distal cadaver femurs and four proximal cadaver tibias from 55- and 62-year-old males. Eight hundred ninety Newton line was used, testing the anchors to failure with an Instron testing device (Instron, Norwood, MA). The anchor devices were inserted randomly and tested blindly (12 tests per anchor device, 60 tests in all). Results: Two anchors in each group tested failed at low loads. Both types of plastic anchors had failures at the eyelet. Average pullout strength varied from 85.4 to 185.6 N. Conclusions: Insertion techniques are specific for each device, and they must be followed for optimal fixation. In this study, in all five groups of anchors tested two of the 12 anchors in each group failed with minimal force. On the basis of this finding we recommend that, if suture anchor fixation is necessary, at least two anchors should be used. Since there appears to be a percentage of failure in all devices, the second anchor can serve as a backup. It is imperative that surgeons be familiar with the insertion techniques of each device before use.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Comparison of Staple, Anchor, and Tenodesis Screw for Posterior Tibialis Tendon Fixation: A Biomechanical Analysis;The Journal of Foot and Ankle Surgery;2023-11

2. A review of suture anchors;Orthopaedics and Trauma;2019-08

3. Interference screw for fixation of FDL transfer in the treatment of adult acquired flat foot deformity stage II;Archives of Orthopaedic and Trauma Surgery;2015-07-24

4. Tendon Transfers—How Do They Work?;Foot and Ankle Clinics;2014-03

5. Tensile Forces on Repaired Medial Meniscal Root Tears;Arthroscopy: The Journal of Arthroscopic & Related Surgery;2013-02