Abstract

Background: Despite uniform operating techniques, lack of fusion still occurs after ankle arthrodesis. Differences in the biological healing potential may be a factor but the mechanical performance of the arthrodesis construct because of varying bone quality also may be important. Internal compression techniques are preferred because of higher union rates, shorter fusion times, and fewer complications. A three-screw configuration has been shown to be more stable than a two-screw configuration, but it is not obvious when it should be used. Methods: Three-dimensional finite element models of intact and flat-cut ankle arthrodeses were built, using two and three screws in different configurations. Poor bone quality was simulated by decreasing Young's modulus of the bone. The constructs were loaded in torsion and dorsiflexion, and micromotions at the fusion site were measured. Results: Bone quality had a marked effect on the stability at the arthrodesis site. Inserting two screws at 30 degrees relative to the longitudinal axis of the tibia in an intact arthrodesis seemed the best option, especially as bone quality worsened. The addition of a third screw increased the stability at the arthrodesis site. Conclusions: Overall, intact joint surfaces and three-screw fixation, with the lateral and medial screws inserted produced the most stable arthrodesis constructs when bone quality was poor. Clinical Relevance. Ankle arthrodeses are technically demanding because of the shape and small size of the talus. Preoperative planning is an absolute necessity to determine placement and number of screws. This study shows that poor bone quality decreases the stability of the arthrodesis constructs, suggesting that an attempt should be made to create the most stable three-screw configuration. Finite element models can be used as an effective preoperative tool for planning screw number and placement.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 26 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3