Biomechanical Comparison of Intramedullary Screw Versus Low-Profile Plate Fixation of a Jones Fracture

Author:

Huh Jeannie1,Glisson Richard R.2,Matsumoto Takumi3,Easley Mark E.2

Affiliation:

1. Department of Orthopaedic Surgery, Dwight D. Eisenhower Army Medical Center, Fort Gordon, GA, USA

2. Department of Orthopaedic Surgery, Duke University Medical Center, Durham, NC, USA

3. The University of Tokyo, Tokyo, Japan

Abstract

Background: Intramedullary screw fixation of fifth metatarsal Jones fractures often produces satisfactory results, however, nonunion and refracture rates are not negligible. The low-profile “hook” plate is an alternative fixation method that has been promoted to offer improved rotational control at the fracture site, but this remains to be proven. The purpose of this study was to document biomechanical performance differences between this type of plate and a contemporary solid, dual-pitch intramedullary screw in a cadaveric Jones fracture model. Methods: Simulated Jones fractures were created in 8 matched pairs of fresh-frozen cadaveric fifth metatarsals. One bone from each pair was stabilized using an intramedullary TriMed Jones Screw and the other using a TriMed Jones Fracture Plate (TriMed, Inc, Santa Clarita, CA). Controlled bending and torsional loads were applied. Bending stiffness and fracture site angulation, as well as torsional stiffness, peak torque, and fracture site rotation were quantified and compared. Results: Intramedullary screw fixation demonstrated greater bending stiffness and less fracture site angulation than plate fixation during plantar-to-dorsal and lateral-to-medial bending. Torsional stiffness of screw-fixed metatarsals exceeded that of plate-fixed bones at initial loading; however, as rotation progressed, the plate resisted torque better than the screw. No difference in peak torque was demonstrable between fixation methods, but it was reached earlier in specimens fixed with screws and later in those fixed with plates as rotation progressed. Conclusion: In this cadaveric Jones fracture model, intramedullary screw fixation demonstrated bending stiffness and resistance to early torsional loading that was superior to that offered by plate fixation. Clinical Relevance: Although low-profile “hook” plates offer an alternative for fixation of fifth metatarsal Jones fractures, intramedullary screw fixation may provide better resistance to bending and initiation of fracture site rotation. The influence of these mechanical characteristics on fracture healing is unknown, and further clinical investigation is warranted.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 39 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3