Two Orthogonal Nitinol Staples and Combined Nitinol Staple-Screw Constructs for a First Metatarsophalangeal Joint Arthrodesis: A Biomechanical Cadaver Study

Author:

Schafer Kevin A.1ORCID,Baldini Todd2ORCID,Hamati Mary2,Backus Jonathon D.1ORCID,Hunt Kenneth J.2ORCID,McCormick Jeremy J.1

Affiliation:

1. Department of Orthopedic Surgery, Washington University in St Louis, St Louis, MO, USA

2. Department of Orthopaedic Surgery, University of Colorado School of Medicine, Aurora, CO, USA

Abstract

Background: End-stage hallux metatarsophalangeal (MTP) joint arthritis is commonly treated with arthrodesis using stainless steel or titanium implants. These implants provide static compression that is maximal at the time of implant insertion. Alternatively, nitinol staples are capable of dynamic compression. They have most frequently been used for midfoot arthrodesis procedures. However, their biomechanical performance during hallux MTP arthrodesis has not been described. Methods: 8 matched pairs of cadaveric feet (4 female, 4 male) were prepared for hallux MTP arthrodesis using cup and cone reamers. Cadaveric pairs were then instrumented with either (1) a transarticular lag screw and dorsal nitinol staple or (2) orthogonal nitinol staples placed dorsally and medially. Walking in a short leg cast for 6 weeks was simulated by applying 90-N forces at 3 Hz to the plantar proximal phalanx for up to 250 000 cycles. Failure was defined as catastrophic implant failure or plantar gapping beyond 7 mm. Results: 15 of 16 specimens failed cyclic loading. All 8 specimens fixed with orthogonal staples failed at an average of 37 ± 81 cycles. 7 of 8 specimens fixed with a dorsal staple and crossed screw failed at 14 900 ± 39 000 cycles. Collectively, 5 specimens failed because of bone fracture (1 in orthogonal staples, 4 in staple-screw group) and 10 failed because of excessive gap formation (7 in orthogonal staples, 3 in staple-screw group). The number of cycles to failure was significantly lower ( P = .0469) in the orthogonal staple constructs compared with the dorsal staple and crossed screw constructs. Conclusion: The tested constructs permit significant motion at the first MTP fusion surface during simulated protected weightbearing. Although multiple in vivo factors should be considered when extrapolating results from this cadaveric study, this motion may result in clinical failure with early postoperative weightbearing protocols. Clinical Relevance: We report the first biomechanical evaluation of hallux MTP arthrodesis using modern nitinol staples in 2 separate constructs.

Funder

DePuy Synthes

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3