3D Biometrics for Hindfoot Alignment Using Weightbearing CT

Author:

Lintz François1,Welck Matthew2,Bernasconi Alessio3,Thornton James2,Cullen Nicholas P.2,Singh Dishan2,Goldberg Andy2

Affiliation:

1. Clinique de l’Union, Ankle and Foot Surgery Center, Saint-Jean, France

2. Foot & Ankle Unit, Royal National Orthopaedic Hospital, Stanmore, Middlesex, United Kingdom

3. Orthopaedics and Traumatology Unit, Department of Public Health, University of Napoli “Federico II,” Napoli, Italy

Abstract

Background: Hindfoot alignment on 2D radiographs can present anatomical and operator-related bias. In this study, software designed for weightbearing computed tomography (WBCT) was used to calculate a new 3D biometric tool: the Foot and Ankle Offset (FAO). We described the distribution of FAO in a series of data sets from clinically normal, varus, and valgus cases, hypothesizing that FAO values would be significantly different in the 3 groups. Methods: In this retrospective cohort study, 135 data sets (57 normal, 38 varus, 40 valgus) from WBCT (PedCAT; CurveBeam LLC, Warrington, PA) were obtained from a specialized foot and ankle unit. 3D coordinates of specific anatomical landmarks (weightbearing points of the calcaneus, of the first and fifth metatarsal heads and the highest and centermost point on the talar dome) were collected. These data were processed with the TALAS system (CurveBeam), which resulted in an FAO value for each case. Intraobserver and interobserver reliability were also assessed. Results: In normal cases, the mean value for FAO was 2.3% ± 2.9%, whereas in varus and valgus cases, the mean was −11.6% ± 6.9% and 11.4% ± 5.7%, respectively, with a statistically significant difference among groups ( P < .001). The distribution of the normal population was Gaussian. The inter- and intraobserver reliability were 0.99 +/- 0.00 and 0.97 +/-0.02 Conclusions: This pilot study suggests that the FAO is an efficient tool for measuring hindfoot alignment using WBCT. Previously published research in this field has looked at WBCT by adapting 2D biometrics. The present study introduces the concept of 3D biometrics and describes an efficient, semiautomatic tool for measuring hindfoot alignment. Level of Evidence: Level III, retrospective comparative study.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine,Surgery

Cited by 130 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3