The effect of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry instrumentation parameters on the matrix-assisted laser desorption/ionization simulated size exclusion chromatography number-mass, average-weight and polydispersity values of dextran against corresponding values obtained by size exclusion chromatography

Author:

Bashir S1,Giannakopulos AE1,Liu J2

Affiliation:

1. Institute of Mass Spectrometry, University of Warwick, Coventry, UK

2. Texas A&M University, Department of Chemistry, Kingsville, TX

Abstract

The matrix-assisted laser desorption/ionization simulated size exclusion chromatography (SECPC) average-number mass, weight average and polydispersity of dextran 1000 were determined by matrix-assisted laser desorption/ionization (MALDI) time-of-flight (TOF) mass spectrometry. The instrument parameters were varied and the SECPC value determined via the Bruker XMASS software was compared to the value obtained from aqueous-phase size exclusion chromatography. The aqueous-phase size exclusion chromatography values for average-number mass, weight average and polydispersity were 1223 Da, 1500 Da and 1.23 (1010 Da, 1270 Da and 1.26 from manufacturer), whereas the SECPC value varied on the instrumental parameters. The factors that had the greatest effect on the average-number mass, weight average and polydispersity were: (most effect on SECPC value) laser attenuation > matrix-analyte molar concentration > matrix-analyte molar ratios > delay extraction time > solvent-system composition > detector delay (least effect on SECPC value). The oligosaccharide signal distribution as a function of laser attenuation indicate that two distinct regions exist in dextran 1000, where one corresponds to the higher mass oligosaccharides (hexasaccharide or greater), while another region corresponds to lower oligosaccharides (tetra-saccharide). This distribution depends upon the crystallization of the biopolymer and the efficiency of desorption/ionization, which yields the SECPC value. There was broad agreement between the SECPC values and size exclusion chromatography values for dextran, although the polydispersity indicated by SECPC was less than size exclusion chromatography (1.10 vs. 1.26). It can be shown that for narrow polydisperse biopolymers the instrumental conditions are less critical in the determination of average-number mass, weight average and polydispersity, although the SECPC Mn, and weight average values are often higher than the corresponding values obtained by aqueous-phase size exclusion chromatography.

Publisher

SAGE Publications

Subject

Spectroscopy,Atomic and Molecular Physics, and Optics,General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3