Checking the integrity of eyes in prone position: A novel application of video laryngoscopes

Author:

Gerber Daniel1ORCID,Eberle Balthasar1,Erdoes Gabor1

Affiliation:

1. Department of Anaesthesiology and Pain Medicine, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland

Abstract

Perioperative visual loss is a rare but severe complication after surgery in prone position. One of several mechanisms is direct ophthalmic compression. This can be avoided through optimal positioning and padding of the head, but position and integrity of the eyes need to be checked at regular intervals. We describe the use of a conventional video laryngoscope during vascular surgery in prone position as a simple solution for intermittent monitoring of external integrity of the eyes and size of the pupils. This requires no additional material and allows documentation of the findings. Our method might reduce complications and improve patient outcome.

Publisher

SAGE Publications

Subject

General Medicine

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Selfie ensures eye safety;Ain-Shams Journal of Anesthesiology;2023-05-13