Range of Motion Testing of a Novel 3D-Printed Synthetic Spine Model

Author:

Bohl Michael A.1,McBryan Sarah1ORCID,Newcomb Anna G. U. S.1,Lehrman Jennifer N.1,Kelly Brian P.1,Nakaji Peter1,Chang Steve W.1,Uribe Juan S.1,Turner Jay D.1,Kakarla U. Kumar1ORCID

Affiliation:

1. Barrow Neurological Institute, St. Joseph’s Hospital and Medical Center, Phoenix, AZ, USA

Abstract

Study Design: Biomechanical model study. Objective: The Barrow Biomimetic Spine (BBS) project is a resident-driven effort to manufacture a synthetic spine model with high biomechanical fidelity to human tissue. The purpose of this study was to investigate the performance of the current generation of BBS models on biomechanical testing of range of motion (ROM) and axial compression and to compare the performance of these models to historical cadaveric data acquired using the same testing protocol. Methods: Six synthetic spine models comprising L3-5 segments were manufactured with variable soft-tissue densities and print orientations. Models underwent torque loading to a maximum of 7.5 N m. Torques were applied to the models in flexion-extension, lateral bending, axial rotation, and axial compression. Results were compared with historic cadaveric control data. Results: Each model demonstrated steadily decreasing ROM on flexion-extension testing with increasing density of the intervertebral discs and surrounding ligamentous structures. Vertically printed models demonstrated markedly less ROM than equivalent models printed horizontally at both L3-4 (5.0° vs 14.0°) and L4-5 (3.9° vs 15.2°). Models D and E demonstrated ROM values that bracketed the cadaveric controls at equivalent torque loads (7.5 N m). Conclusions: This study identified relevant variables that affect synthetic spine model ROM and compressibility, confirmed that the models perform predictably with changes in these print variables, and identified a set of model parameters that result in a synthetic model with overall ROM that approximates that of a cadaveric model. Future studies can be undertaken to refine model performance and determine intermodel variability.

Publisher

SAGE Publications

Subject

Clinical Neurology,Orthopedics and Sports Medicine,Surgery

Reference7 articles.

1. The Barrow Biomimetic Spine

2. Newcomb A. Variations among human spine segments and their relationships to in vitro kinematics: a retrospective analysis of 281 motion segments from 85 cadaveric spines [abstract 571]. Paper presented at: the International Society for the Advancement of Spine Surgery; April 13, 2017; Boca Raton, FL.

Cited by 13 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3