Radiographic Evaluation of Minimally Invasive Instrumentation and Fusion for Treating Unstable Spinal Column Injuries

Author:

Cavanaugh Daniel1,Usmani M. Farooq2,Weir Tristan B.2,Camacho Jael2,Yousaf Imran2,Khatri Vishal2,Bivona Louis3,Shasti Mark2,Koh Eugene Y.2,Banagan Kelley E.2,Ludwig Steven C.2ORCID,Gelb Daniel E.2

Affiliation:

1. University of North Carolina at Chapel Hill, Chapel Hill, NC, USA

2. University of Maryland School of Medicine, Baltimore, MD, USA

3. Cooper University Health Care, Baltimore, MD, USA

Abstract

Study Design: Retrospective cohort. Objective: Facet fusion in minimally invasive spine surgery (MISS) may reduce morbidity and promote long-term construct stability. The study compares the maintenance of correction of thoracolumbar (TL) trauma patients who underwent MISS with facet fusion (FF) and without facet fusion (WOFF) and evaluates instrumentation loosening and failure. Methods: TL trauma patients who underwent MISS between 2006 and 2013 were identified and stratified into FF and WOFF groups. To evaluate progressive kyphosis and loss of correction, Cobb angles were measured at immediate postoperative, short-term, and long-term follow-up. Evidence of >2 mm of radiolucency on radiographs indicated screw loosening. If instrumentation was removed, postremoval kyphosis angle was obtained. Results: Of the 80 patients, 24 were in FF and 56 were in WOFF group. Between immediate postoperative and short-term follow-up, kyphosis angle changed by 4.0° (standard error [SE] 1.3°) in the FF and by 3.0° (SE 0.4°) in the WOFF group. The change between immediate postoperative and long-term follow-up kyphosis angles was 3.4° (S.E 1.1°) and 5.2° (S.E 1.6°) degrees in the FF and WOFF groups, respectively. Facet fusion had no impact on the change in kyphosis at short term ( P = .49) or long term ( P = .39). The screw loosening rate was 20.5% for the 80 patients with short-term follow-up and 68.8% for the 16 patients with long-term follow-up. There was no difference in screw loosening rate. Fifteen patients underwent instrumentation removal—all from the FF group. Conclusion: FF in MISS does not impact the correction achieved and maintenance of correction in patients with traumatic spine injuries.

Publisher

SAGE Publications

Subject

Clinical Neurology,Orthopedics and Sports Medicine,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3