Glenoid Version Assessment When the CT Field of View Does Not Permit the Friedman Method: The Robertson Method

Author:

Robertson Douglas D.123,Sharma Gulshan B.4,McMahon Patrick J.56,Karas Spero G.23

Affiliation:

1. Author deceased.

2. Emory Orthopaedics and Spine Center, Atlanta, Georgia, USA.

3. Department of Biomedical Engineering, Georgia Institute of Technology and Emory University, Atlanta, Georgia, USA

4. Department of Psychiatry, Cumming School of Medicine, University of Calgary, Calgary, Alberta, Canada.

5. VA Pittsburgh Healthcare System, Pittsburgh, Pennsylvania, USA.

6. Department of Orthopedic Surgery and Department of Bioengineering, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.

Abstract

Background: To improve spatial resolution, current clinical shoulder cross-sectional imaging studies reduce the field of view of the shoulder, excluding the medial scapula border and preventing glenoid version measurement according to the Friedman method. Purpose: To evaluate a method to accurately and reliably measure glenoid version on cross-sectional shoulder images when the medial scapula border is not included in the field of view, and to establish measurements equivalent to the Friedman method. Study Design: Controlled laboratory study. Methods: Sixty-five scapulae underwent computed tomography (CT) scanning with an optimal shoulder CT-positioning protocol. Glenoid version was measured on CT images of the full scapula using the Friedman method. We developed a measurement method (named the Robertson method) based on the glenoid vault version from partial scapula images, with a correction angle subtracted from the articular-surface-glenoid vault measurement. Comparison with the Friedman method defined the accuracy of the Robertson method. Three observers tested inter- and intraobserver reliability of the Robertson method. Accuracy was statistically evaluated with t tests and reliability with the intraclass correlation coefficient (ICC). Results: The statistical distribution of glenoid version was similar to published data,–0.5° ± 3° [mean ± SD]. The initial measurement using the Robertson method resulted in a more retroverted angle compared with the Friedman method, and a correction angle of 7° was then applied. After this adjustment, the difference between the 2 methods was nonsignificant (0.1° ± 4°; P > .65). Reliability of the Robertson method was excellent, as the interrater ICC was 0.77, the standard error of measurement (SEM) was 1.1° with P < .001. The intrarater ICC ranged between 0.84 and 0.92, the SEM ranged between 0.9° and 1.2° with P < .01. Conclusion: A validated glenoid version measurement method is now available for current clinical shoulder CT protocols that reliably create Friedman-equivalent values. Clinical Relevance: Friedman-equivalent values may be made from common clinical CTs of the shoulder and compared with prior and future Friedman measurements of the scapula.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3