Affiliation:
1. Division of Orthopaedic Surgery, Rady Children’s Hospital, San Diego, California, USA.
2. Department of Orthopaedic Surgery, University of California-San Diego, San Diego, California, USA.
Abstract
Background: Previous studies have suggested that suture tape-reinforced anterior cruciate ligament (ACL) grafts may have higher ultimate failure loads without stress-shielding. In patients at high risk for graft failure, such as adolescents, the addition of suture tape could have beneficial outcomes. Hypothesis: Suture tape reinforcement (STR) of ACL grafts in adolescent patients would lead to fewer graft ruptures during early recovery, without hindering subjective outcomes. Study Design: Cohort study; Level of evidence, 3. Methods: A retrospective review was performed on adolescent patients with a minimum 2-year follow-up after hamstring tendon autograft ACL reconstruction; enrolled were patients from both before (n = 40) and after (n = 40) a shift in surgical technique that added STR. Both the no-STR and the STR cohorts were contacted yearly to obtain patient-reported outcome data for visual analog scale (VAS; range, 0-10) for pain score, Single Assessment Numeric Evaluation, Lysholm score, Tegner activity score, patient satisfaction score (range, 0-100), and return to previous level of sport (yes/no). The cohorts were then matched based on follow-up duration, excluding those with follow-up of <2 years and >3 years to maintain consistency in duration of follow-up. Graft failure was defined as either graft rupture or recurrent instability symptoms, and failures occurring from index procedure to the 3-year mark were recorded for calculations of failure rate. Results: There were no differences between cohorts in mean age [STR, 15.7 years (range, 9.5-18.7 years); no STR, 14.9 years (range, 9.3-18.8 years)], follow-up duration, laterality, or graft size. While not statistically significant, 2 (5%) patients in the STR cohort experienced graft rupture compared with 7 (17.5%) patients in the no-STR cohort. The Tegner score was significantly higher in the STR cohort ( P = .017); no between-group differences were seen on the other outcome scores. A subanalysis of the STR cohort comparing small-diameter grafts (<8 mm) with grafts ≥8 mm also demonstrated no difference in outcome measures, with 1 graft failure in each cohort. Conclusion: Study outcomes indicated that patients treated with ACL reconstruction and STR experienced a significant improvement in Tegner scores while at the same time maintaining the other subjective outcomes.
Subject
Orthopedics and Sports Medicine
Cited by
15 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献