Biomechanical Comparison of a First- and a Second-Generation All-Soft Suture Glenoid Anchor

Author:

Erickson John1,Chiarappa Frank1,Haskel Jonathan1,Rice Justin1,Hyatt Adam1,Monica James1,Dhawan Aman2

Affiliation:

1. Department of Orthopaedics, Rutgers–Robert Wood Johnson Medical School (UMDNJ Legacy), New Brunswick, New Jersey, USA.

2. Penn State Hershey Bone and Joint Institute, Hershey, Pennsylvania, USA.

Abstract

Background: All–soft tissue suture anchors provide advantages of decreased removal of bone and decreased glenoid volume occupied compared with traditional tap or screw-in suture anchors. Previous published data have led to biomechanical concerns with the use of first-generation all-soft suture anchors. Purpose/Hypothesis: The purpose of this study was to evaluate the load to 2-mm displacement and ultimate load to failure of a second-generation all-soft suture anchor, compared with a first-generation anchor and a traditional PEEK (polyether ether ketone) anchor. The null hypothesis was that the newer second-generation anchor will demonstrate no difference in loads to 2-mm displacement after cycling compared with first-generation all-soft suture anchors. Study Design: Controlled laboratory study. Methods: Twenty human cadaveric glenoids were utilized to create 97 total suture anchor sites, and 1 of 3 anchors were randomized and placed into each site: (1) first-generation all-soft suture anchor (Juggerknot; Biomet), (2) second-generation all-soft suture anchor (Suturefix; Smith & Nephew), and (3) a control PEEK anchor (Bioraptor; Smith & Nephew). After initial cyclic loading, load to 2 mm of displacement and ultimate load to failure were measured for each anchor. Results: After cyclic loading, the load to 2-mm displacement was significantly less in first-generation anchors compared with controls ( P < .01). However, the load to 2-mm displacement was significantly greater in second-generation anchors compared with controls ( P < .01). There was no difference in ultimate load to failure between the first- and second-generation all-soft suture anchors ( P > .05). Conclusion: The newer generation all-soft suture anchors with a theoretically more rigid construct and deployment configuration demonstrate biomechanical characteristics (specifically, with load to 2-mm displacement after cyclic loading) that are improved over first-generation all-soft suture anchors and similar to a traditional solid tap-in anchor. The configuration of these newer generation all-soft suture anchors appears to mitigate the biomechanical concerns of decreased load to failure with first-generation all–soft tissue suture anchors. Clinical Relevance: The theoretical advantages of all-soft anchors may be particularly valuable in revision surgery or in cases where multiple anchors are being placed into a small anatomic area.

Publisher

SAGE Publications

Subject

Orthopedics and Sports Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3